Primary Standard Platinum Resistance Thermometer (SPRT) -200 °C to 670 °C

5.245,00 

Model: eXacal 230 Manufacturer: Klasmeier

Description

The eXacal Model 230 is a high-precision Standard Platinum Resistance Thermometer (SPRT) specifically developed for use in metrological laboratories. It offers exceptional stability, low measurement uncertainties, and is perfectly aligned with the requirements of the International Temperature Scale (ITS-90). With a measurement range of -200 °C to +670 °C, it is the ideal choice for calibrations in research and industry.

Features

Precision: Outstanding measurement accuracy with minimal uncertainties.

Temperature Range: The Standard Platinum Resistance Thermometer (SPRT) is suitable for temperatures from -200 °C to +670 °C.

Quality: Manufactured from high-purity platinum for maximum stability and reliability.

Traceability: The eXacal 230 Standard Platinum Resistance Thermometer fully complies with the requirements of ITS-90.

Applications

• Calibration of industrial sensors and reference thermometers

• Precise temperature measurements in metrological laboratories

• Traceability of temperature measurements to international standards

Accredited Calibration according to DIN EN ISO/IEC 17025

In our accredited calibration laboratory according to DIN EN ISO/IEC 17025 (DAkkS), we calibrate Standard Platinum Resistance Thermometers (SPRTs) with the highest precision. For each calibrated thermometer, you receive a calibration certificate documenting traceability and the stated measurement uncertainty.

Measurement Uncertainty of Standard Platinum Resistance Thermometer (SPRT)

eXacal 230 - Standard Platinum Resistance Thermometer

Measurement Uncertainties by Temperature Range

Temperature RangeFixed PointsMeasurement Uncertainty
-189.3442 °C – 0.01 °CArgon to Water Triple Point5.5 mK
-38.8344 °C – 29.7646 °CMercury to Gallium3.5 mK
0.01 °C – 29.7646 °CWater Triple Point to Gallium2.5 mK
0.01 °C – 420.527 °CWater Triple Point to Zinc4.5 mK
0.01 °C – 660.323 °CWater Triple Point to Aluminum7.0 mK

Measurement Uncertainties at ITS-90 Fixed Points

TemperatureFixed PointMeasurement Uncertainty
-189.3442 °CArgon4.0 mK
-38.8344 °CMercury2.5 mK
0.01 °CWater Triple Point1.5 mK
29.7646 °CGallium2.0 mK
231.928 °CTin3.0 mK
419.527 °CZinc3.0 mK
660.323 °CAluminum5.0 mK

The stated measurement uncertainties correspond to k=2 and take into account the ITS-90 deviation function and self-heating.

Learn more about our calibration laboratory:

Calibration of Standard Platinum Resistance Thermometers

Temperature Sensors from our Own Manufacturing Facility

Every temperature sensor of the eXacal 230 Standard Platinum Resistance Thermometer (SPRT) is manufactured with the utmost care and precision in our in-house facility in Fulda. The development and production of our own measuring resistors guarantee the highest quality and reliability.

Why Klasmeier Manufacturing?
• Craftsmanship Precision: Our SPRTs are manufactured by experienced experts who carefully monitor every detail.
• Individual Solutions: We can address specific requirements and produce customized sensors for your application.
• Quality Control: Every sensor undergoes strict testing procedures to ensure it meets the high requirements of the International Temperature Scale ITS-90.

By manufacturing in our own facility, we have full control over the entire production process – from material selection to final accredited calibration. The result: a product that meets the highest demands in measurement technology.

Technical Specifications

Technical Data Model 230
Model eXacal 230
Temperature Range -200 °C to 670 °C
Nominal Resistance Pt25 (approx. 25.5 Ohm)
Connection Type Four-wire
Connector Lug Connector
Sheath Material Quartz
Thermometer Wire Platinum
Dimensions
Handle ⌀ 20 mm x 100 mm
Sheath Diameter ⌀ 7.5 mm
Sheath Length 500 mm
Sheath Filling Protective Gas
Cable Length 2 m
Measuring Element / Temperature Sensor
Length 40 mm
Type Quartz (complies with ITS-90 requirements)
Recommended Measuring Current 1 mA
Self-Heating 1 mA at the Gallium Fixed Point
W Value W-Gallium ≥ 1.11807 (complies with ITS-90 requirements)
Calibration
Fixed-Point Calibration

As an option, we offer accredited fixed-point calibration in accordance with DIN EN ISO/IEC 17025 within the scope of our DAkkS accreditation. The calibration is carried out at ITS-90 temperature fixed points.
The temperature range and calibration points can be coordinated depending on the application and the desired scope of calibration. The achievable measurement uncertainties depend on the selected method and are documented in the calibration certificate.

Calibration certificate

Upon completion of the calibration, you will receive a calibration certificate that provides a clear and traceable record of the calibration procedure and results. Among other things, the calibration certificate includes information on the calibrated measuring instrument, the calibration method applied, the reference standards used, the measurement conditions, the calibration results, and the measurement uncertainty.
This enables you to evaluate the measurement results on a technical basis and to document them for your quality assurance and test equipment monitoring.