Primary Standard Platinum Resistance Thermometer (SPRT) -200 °C to 670 °C

5.245,00 €

Model: eXacal 230 Manufacturer: Klasmeier

Description

The eXacal Model 230 is a high-precision Standard Platinum Resistance Thermometer (SPRT) specifically developed for use in metrological laboratories. It offers exceptional stability, low measurement uncertainties, and is perfectly aligned with the requirements of the International Temperature Scale (ITS-90). With a measurement range of -200 °C to +670 °C, it is the ideal choice for calibrations in research and industry.

Features

• Precision: Outstanding measurement accuracy with minimal uncertainties.

• Temperature Range: The Standard Platinum Resistance Thermometer (SPRT) is suitable for temperatures from -200 °C to +670 °C.

• Quality: Manufactured from high-purity platinum for maximum stability and reliability.

• Traceability: The eXacal 230 Standard Platinum Resistance Thermometer fully complies with the requirements of ITS-90.

Applications

• Calibration of industrial sensors and reference thermometers

• Precise temperature measurements in metrological laboratories

• Traceability of temperature measurements to international standards

Accredited Calibration according to DIN EN ISO/IEC 17025

Full Range -196 °C to 660 °C

Scope of Services: SPRT freezing point calibration Full Range -196 °C to 660 °C. With Argon, Mercury, Water Triple Point, Gallium, Tin, Zinc, and Aluminum

Calibrations in specific temperature ranges

KK-1400 – SPRT freezing point calibration from -196 °C to 29 °C (Argon, Mercury, Water Triple Point, and Gallium)

KK-1401 – SPRT freezing point calibration from 0 °C to 420 °C (Water Triple Point, Gallium, Tin, and Zinc)

KK-1402 – SPRT freezing point calibration from 0 °C to 660 °C (Water Triple Point, Gallium, Tin, Zinc, and Aluminum)

In our accredited calibration laboratory according to DIN EN ISO/IEC 17025 (DAkkS), we calibrate Standard Platinum Resistance Thermometers (SPRTs) with the highest precision. For each calibrated thermometer, you receive a calibration certificate documenting traceability and the stated measurement uncertainty.

Measurement Uncertainty Standard Platinum Resistance Thermometer (SPRT)

eXacal 230 - Standard Platinum Resistance Thermometer

Measurement Uncertainties by Temperature Range

Temperature RangeFixed PointsMeasurement Uncertainty
-189.3442 °C – 0.01 °CArgon to Water Triple Point5.5 mK
-38.8344 °C – 29.7646 °CMercury to Gallium3.5 mK
0.01 °C – 29.7646 °CWater Triple Point to Gallium2.5 mK
0.01 °C – 420.527 °CWater Triple Point to Zinc4.5 mK
0.01 °C – 660.323 °CWater Triple Point to Aluminum7.0 mK

The stated measurement uncertainties correspond to k=2, and take into account the ITS-90 deviation function as well as self-heating.

Measurement Uncertainties at ITS-90 Fixed Points

TemperatureFixed PointMeasurement Uncertainty
-189.3442 °CArgon4.0 mK
-38.8344 °CMercury2.5 mK
0.01 °CWater Triple Point1.5 mK
29.7646 °CGallium2.0 mK
231.928 °CTin3.0 mK
419.527 °CZinc3.0 mK
660.323 °CAluminum5.0 mK

Learn more about our calibration laboratory:

Calibration of Standard Platinum Resistance Thermometers

Temperature Sensors from Our Own Manufacturing Facility

Every temperature sensor of the eXacal 230 Standard Platinum Resistance Thermometer (SPRT) is manufactured with the utmost care and precision in our in-house facility in Fulda. The development and production of our own measuring resistors guarantee the highest quality and reliability.

Why Klasmeier Manufacturing?
• Craftsmanship Precision: Our SPRTs are manufactured by experienced experts who carefully monitor every detail.
• Individual Solutions: We can address specific requirements and produce customized sensors for your application.
• Quality Control: Every sensor undergoes strict testing procedures to ensure it meets the high requirements of the International Temperature Scale ITS-90.

By manufacturing in our own facility, we have full control over the entire production process – from material selection to final accredited calibration. The result: a product that meets the highest demands in measurement technology.

Further SPRTs in the series:

Technical Data

Technical Data Model 230
Model eXacal 230
Temperature Range -200 °C to 670 °C
Nominal Resistance Pt25 (25.5 Ohms, tolerance ±1 Ohm)
Connection Type Four-wire
Connection gold-plated crimp lugs
Sheath Material Quartz
Thermometer Wire Platinum
Dimensions
Handle ⌀ 20 mm x 100 mm
Protective Tube Diameter ⌀ 7.5 mm
Protective Tube Length 500 mm
Protective Tube Filling Protective gas
Connection Cable 2 m
Measuring Resistor / Temperature Sensor
Length 40 mm
Type Quartz (according to ITS-90 requirements)
Recommended Measuring Current 1 mA
Self-heating 1 mA at Gallium fixed point
W-value W-Gallium ≥ 1.11807 (according to ITS-90 requirements)
Calibration
Fixed-Point Calibration

Optionally, we offer an accredited fixed-point calibration according to DIN EN ISO/IEC 17025 within the scope of our DAkkS accreditation. Calibration is performed at ITS-90 temperature fixed points.
Temperature range and calibration points can be coordinated depending on the application and desired calibration scope. The achievable measurement uncertainties result from the chosen procedure and are documented in the calibration certificate.

Calibration Certificate

With the calibration, you receive a calibration certificate that comprehensibly documents the execution and results of the calibration. The calibration certificate includes, among other things, information on the calibrated measuring instrument, the calibration procedure used, the reference standards used, the measurement conditions, the calibration results, and the measurement uncertainty.
For the calibration of SPRTs, the calibration certificate additionally includes two calibration curves for different measuring currents. This allows the influence of the measuring current and the resulting self-heating on the calibration results to be comprehensibly taken into account.
This provides a reliable basis for the professional evaluation of measurement results and for your quality and test equipment monitoring.

Downloads

Manual Model 230 – German Manual Model 230 – English