Blackbody Calibrators

ISOTECH Blackbody Calibrators

Primary Radiation Sources for Pyrometer Calibration

Find the right ISOTECH infrared calibrator for testing and calibrating infrared thermometers and pyrometers. With these calibrators / blackbody calibrators / blackbody radiation sources for infrared thermometers, you can calibrate thermal imaging cameras and infrared thermometers very easily, quickly, and precisely.

Infrared Thermometers / Handheld Pyrometers
No-touch Forehead Thermometers
Contactless Fever Thermometers in Medical Applications
Pediatric Thermometers

Infrared calibrator for testing and calibrating infrared thermometers and pyrometers. Often used in medical facilities for testing contactless fever thermometers.

Includes Reference Thermometer
The calibrator is supplied with a reference thermometer and a built-in display unit. Both can be provided with a DAkkS calibration certificate.
True Cavity Blackbody
The blackbody is designed as a true cavity radiator. This eliminates negative effects that occur with flat radiators (such as drafts and reflections).

With this calibrator / blackbody calibrator / blackbody radiation source for infrared thermometers, thermal imaging cameras and infrared thermometers operating near room temperature can be calibrated very easily, quickly, and precisely. These include, for example:

Contactless Fever Thermometers in Medical Applications
Pediatric Thermometers
Infrared Thermometers / Pyrometers
No-touch Forehead Thermometers

The Quick-Cal offers an economical solution for calibrating and testing infrared thermometers. The blackbody calibrator is portable, making it ideal for quick checks of infrared thermometers.

Reference Temperature: 30 °C to 350 °C
Combined Stability/Uncertainty of ±0.2 °C/±0.5 °C
The Temperature Controller has a Resolution of 0.1 °C
Emissivity is Better than 0.97 ±0.02

The portable Gemini R 550 blackbody calibrator enables the calibration of non-contact infrared thermometers over a temperature range of 30 °C to 550 °C. It is suitable for use as a primary radiation source for infrared thermometers.

Primary Radiation Source (Blackbody Calibrator) for Medium-Temperature Pyrometers
65mm Cavity Diameter
0.995 Emissivity Factor
Lightweight and Compact
Also Suitable for Fixed-Point Cells

The Pegasus R is a calibration furnace in which radiation pyrometers can be calibrated.

Temperature Range: 150 °C to 1200 °C
Primary Radiation Source (Blackbody Calibrator) for High-Temperature Pyrometers
Cavity Construction
Emissivity Factor 0.995
Compact and Lightweight
Fixed-Point Cells Can Be Used