The low-temperature precision thermometers are used for precise temperature measurements or as calibration standards.

NEW design: gas-tight handle with protective gas filling

Temperature range: -200 °C to 250 °C

low measurement uncertainties: 11 mK to 13 mK

robust alternative to ITS-90 Standard Platinum Resistance Thermometers (SPRTs)

high stability and excellent calibration capability

low temperature down to -200 °C due to protective gas

New design: gas-tight handle with protective gas filling

Due to the new design of the gas-tight handle, the protection tube of the low-temperature precision thermometer can be filled with a protective gas. This improves the thermometer’s characteristics and extends the temperature range down to extremely low temperatures of -200 °C. This allows the low-temperature precision thermometer to be calibrated down to the argon triple point at approx. -189 °C.

Not the right product for you?

DAkkS Calibration at Temperature Fixed Points

Low-temperature precision thermometers can be calibrated in our own DAkkS calibration laboratory. DAkkS accreditation ensures that all calibrations are traceable to national and international standards.

The low-temperature precision thermometers have been designed for excellent calibration at temperature fixed points down to the argon triple point. The measurement uncertainty is calculated from many components. The largest contributions to the measurement uncertainty budget are the reproducibility of the thermometer, ITS-90 deviation function, self-heating, and hysteresis of the temperature sensor. Using the parameters from the calibration certificate, the low-temperature precision thermometer can be used with the respective deviation function in the temperature range from -189 °C to 232 °C.

DAkkS Measurement Uncertainty

low measurement uncertainties with DAkkS calibration certificate

Temperature fixed points from argon triple point -189.3442 °C to tin freezing point 231.928 °C

RangeTemperature Fixed PointsMeasurement Uncertainty
-189.3442 °C – 0.01 °C Argon to Water12 mK
-38.8344 °C – 0.01 °CMercury to Water10 mK
0.01 °C – 29.7646 °CWater to Gallium12 mK
0.01 °C – 156.5985 °CWater to Indium11 mK
0.01 °C – 231.928 °CWater to Tin11 mK
The stated measurement uncertainties correspond to k=2, include an ITS-90 deviation function, self-heating, and hysteresis, and are specified for the respective range.

Technical Data

Model eXacal Pt100L
Temperature range -200 °C to 250 °C
Nominal resistance Pt100 (approx. 100 Ohm)
typical annual drift 2.5 mK
Connection type Four-wire
Connection Banana plug
Sheath material Metal
Thermometer wire Platinum
Dimensions
Handle ø 20 mm x 100 mm
Protection tube diameter ø 6 mm
Protection tube length 400 mm
Protection tube filling Protective gas
Connection cable 2 m
Max. immersion depth 350 mm
Measuring resistor / Temperature sensor
Length 25 mm
recommended measuring current 1 mA
Self-heating 5 mK – 10 mK
Calibration
Fixed-point calibration 11 mK to 13 mK