{"id":7508,"date":"2024-11-21T09:32:37","date_gmt":"2024-11-21T08:32:37","guid":{"rendered":"https:\/\/www.klasmeier.com\/produkt\/primaeres-standard-platin-widerstandsthermometer-sprt-200-c-bis-670-c\/"},"modified":"2026-08-05T10:23:43","modified_gmt":"2026-08-05T08:23:43","slug":"standard-platinum-resistance-thermometer","status":"publish","type":"product","link":"https:\/\/www.klasmeier.com\/en\/produkt\/standard-platinum-resistance-thermometer\/","title":{"rendered":"Primary Standard Platinum Resistance Thermometer (SPRT) <b>-200 \u00b0C to 670 \u00b0C<\/b>"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"82\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png\" alt=\"\" class=\"wp-image-4288\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png 449w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited-300x55.png 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/figure>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">The <strong>eXacal Model 230<\/strong> is a high-precision Standard Platinum Resistance Thermometer (SPRT) specifically developed for use in metrological laboratories. It offers exceptional stability, low measurement uncertainties, and is perfectly aligned with the requirements of the International Temperature Scale (ITS-90). With a measurement range of <strong>-200 \u00b0C to +670 \u00b0C<\/strong>, it is the ideal choice for calibrations in research and industry.  <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Features<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>Precision:<\/strong> Outstanding measurement accuracy with minimal uncertainties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>Temperature Range:<\/strong> The Standard Platinum Resistance Thermometer (SPRT) is suitable for temperatures from <strong>-200 \u00b0C to +670 \u00b0C<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>Quality:<\/strong> Manufactured from high-purity platinum for maximum stability and reliability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>Traceability:<\/strong> The eXacal 230 Standard Platinum Resistance Thermometer fully complies with the requirements of ITS-90.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-medium\"><img data-dominant-color=\"060f16\" data-has-transparency=\"true\" style=\"--dominant-color: #060f16;\" loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp\" alt=\"\" class=\"wp-image-13158 has-transparency\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-150x150.webp 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-768x768.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-600x600.webp 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-100x100.webp 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent.webp 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\"><strong>Applications<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u2022 Calibration of industrial sensors and reference thermometers<\/p>\n\n<p class=\"wp-block-paragraph\">\u2022 Precise temperature measurements in metrological laboratories<\/p>\n\n<p class=\"wp-block-paragraph\">\u2022 Traceability of temperature measurements to international standards<\/p>\n\n<h2 class=\"wp-block-heading\">Accredited Calibration according to DIN EN ISO\/IEC 17025<\/h2>\n\n<p class=\"wp-block-paragraph\">In our <strong>accredited calibration laboratory according to DIN EN ISO\/IEC 17025 (DAkkS)<\/strong>, we calibrate Standard Platinum Resistance Thermometers (SPRTs) with the highest precision. For each calibrated thermometer, you receive a calibration certificate documenting traceability and the stated measurement uncertainty. <\/p>\n\n<h3 class=\"wp-block-heading\">Measurement Uncertainty of Standard Platinum Resistance Thermometer (SPRT)<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"f7f7f8\" data-has-transparency=\"false\" style=\"--dominant-color: #f7f7f8;\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"585\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-1024x585.webp\" alt=\"eXacal 230 - Standard Platinum Resistance Thermometer\" class=\"wp-image-7766 not-transparent\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-1024x585.webp 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-300x171.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-768x439.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-1536x878.webp 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-2048x1170.webp 2048w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-230-eXacal-Klasmeier-600x343.webp 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h3 class=\"wp-block-heading\">Measurement Uncertainties by Temperature Range<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-right\" data-align=\"right\"><strong>Temperature Range<\/strong><\/td><td><strong>Fixed Points<\/strong><\/td><td><strong>Measurement Uncertainty<\/strong><\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">-189.3442 \u00b0C \u2013 0.01 \u00b0C<\/td><td>Argon to Water Triple Point<\/td><td>5.5 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">-38.8344 \u00b0C \u2013 29.7646 \u00b0C<\/td><td>Mercury to Gallium<\/td><td>3.5 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">0.01 \u00b0C \u2013 29.7646 \u00b0C<\/td><td>Water Triple Point to Gallium<\/td><td>2.5 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">0.01 \u00b0C \u2013 420.527 \u00b0C<\/td><td>Water Triple Point to Zinc<\/td><td>4.5 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">0.01 \u00b0C &#8211; 660.323 \u00b0C<\/td><td>Water Triple Point to Aluminum<\/td><td>7.0 mK<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<div style=\"height:9px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Measurement Uncertainties at ITS-90 Fixed Points<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-right\" data-align=\"right\"><strong>Temperature<\/strong><\/td><td><strong>Fixed Point<\/strong><\/td><td><strong>Measurement Uncertainty<\/strong><\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">-189.3442 \u00b0C<\/td><td>Argon<\/td><td>4.0 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">-38.8344 \u00b0C<\/td><td>Mercury<\/td><td>2.5 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">0.01 \u00b0C<\/td><td>Water Triple Point<\/td><td>1.5 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">29.7646 \u00b0C<\/td><td>Gallium<\/td><td>2.0 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">231.928 \u00b0C<\/td><td>Tin<\/td><td>3.0 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">419.527 \u00b0C<\/td><td>Zinc<\/td><td>3.0 mK<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">660.323 \u00b0C<\/td><td>Aluminum<\/td><td>5.0 mK<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">The stated measurement uncertainties correspond to k=2 and take into account the ITS-90 deviation function and self-heating.<\/p>\n\n<p class=\"wp-block-paragraph\">Learn more about our calibration laboratory:<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.klasmeier.com\/en\/kalibrierdienst-klasmeier\/kalibrierung-von-normalthermometern\/\">Calibration of Standard Platinum Resistance Thermometers<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Temperature Sensors from our Own Manufacturing Facility<\/h2>\n\n<p class=\"wp-block-paragraph\">Every temperature sensor of the eXacal 230 Standard Platinum Resistance Thermometer (SPRT) is manufactured with the utmost care and precision in our in-house facility in Fulda. The development and production of our own measuring resistors guarantee the highest quality and reliability. <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Why Klasmeier Manufacturing?<\/strong><br\/><strong>\u2022 Craftsmanship Precision:<\/strong> Our SPRTs are manufactured by experienced experts who carefully monitor every detail.<br\/><strong>\u2022 Individual Solutions: <\/strong>We can address specific requirements and produce customized sensors for your application.<br\/><strong>\u2022 Quality Control:<\/strong> Every sensor undergoes strict testing procedures to ensure it meets the high requirements of the International Temperature Scale ITS-90.<\/p>\n\n<p class=\"wp-block-paragraph\">By manufacturing in our own facility, we have full control over the entire production process \u2013 from material selection to final accredited calibration. The result: a product that meets the highest demands in measurement technology. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Model: eXacal 230 Manufacturer: Klasmeier<\/p>\n","protected":false},"featured_media":6472,"template":"","meta":[],"product_brand":[],"product_cat":[423],"product_tag":[405,425],"class_list":["post-7508","product","type-product","status-publish","has-post-thumbnail","product_cat-standard-platinum-resistance-thermometer","product_tag-sprt-en","product_tag-standard-platin-widerstandsthermometer-sprt-en","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product\/7508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media\/6472"}],"wp:attachment":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media?parent=7508"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_brand?post=7508"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_cat?post=7508"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_tag?post=7508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}