{"id":17112,"date":"2024-02-29T17:17:11","date_gmt":"2024-02-29T16:17:11","guid":{"rendered":"https:\/\/www.klasmeier.com\/produkt\/pt100-model-l-low-temperature-precision-thermometer-200-c-to-250-c\/"},"modified":"2026-10-28T11:13:06","modified_gmt":"2026-10-28T10:13:06","slug":"pt100-model-l-low-temperature-precision-thermometer-200-c-to-250-c","status":"publish","type":"product","link":"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-model-l-low-temperature-precision-thermometer-200-c-to-250-c\/","title":{"rendered":"Pt100 Model L Low-Temperature Precision Thermometer (-200 \u00b0C to 250 \u00b0C)"},"content":{"rendered":"\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-12cf9d4c wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"82\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png\" alt=\"\" class=\"wp-image-4288\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png 449w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited-300x55.png 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The low-temperature precision thermometers are used for precise temperature measurements or as calibration standards.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>NEW Design: gas-tight handle with protective gas filling<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> Temperature range: <strong>-200 \u00b0C to 250 \u00b0C<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> low measurement uncertainties: <strong>11 mK to 13 mK<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> robust alternative to ITS-90 Standard Platinum Resistance Thermometers (SPRTs)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> high stability and good calibratability<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>low temperature down to -200\u00b0C due to protective gas <\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp\" alt=\"\" class=\"wp-image-13158\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-150x150.webp 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-768x768.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-600x600.webp 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-100x100.webp 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent.webp 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-5f2c23f0 wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image alignleft size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/3D-Druck-eXacal-1-150x150-1.jpg\" alt=\"\" class=\"wp-image-4656\" style=\"border-radius:50px;width:225px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/3D-Druck-eXacal-1-150x150-1.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/3D-Druck-eXacal-1-150x150-1-100x100.jpg 100w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<h4 class=\"wp-block-heading\"><strong>New Design: Gas-Tight Handle with Protective Gas Filling<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks to the new design of the gas-tight handle, the protective tube of the low-temperature precision thermometer can be filled with a protective gas. This improves the thermometer&#8217;s properties and extends its temperature range down to extremely low -200 \u00b0C. Thus, the low-temperature precision thermometer can be calibrated down to the argon triple point at approximately -189 \u00b0C.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-b7a9e8ab wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-container-core-column-is-layout-8c381d87 wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-center\">Not the Right Product for You?<\/h2>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/high-quality-temperature-measurement-technology-for-precise-results\/\">-&gt; Back to Overview<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-96971e18 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<h3 class=\"wp-block-heading\">DAkkS Calibration at Temperature Fixed Points<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Low-temperature precision thermometers can be calibrated in our own <a href=\"https:\/\/www.klasmeier.com\/en\/precise-temperature-calibration-from-klasmeier-calibration-service\/\">DAkkS calibration laboratory<\/a>. DAkkS accreditation ensures that all calibrations are traceable to national and international standards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The low-temperature precision thermometers have been designed to be highly suitable for calibration at temperature fixed points down to the argon triple point. The measurement uncertainty is calculated from many components. The largest contributions to the measurement uncertainty budget are the thermometer&#8217;s reproducibility, ITS-90 deviation function, self-heating, and hysteresis of the temperature sensor. With the parameters from the calibration certificate, the low-temperature precision thermometer can be used with the respective deviation function in the temperature range of -189 \u00b0C to 232 \u00b0C.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-5f2b14c0 wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/precise-temperature-calibration-from-klasmeier-calibration-service\/calibration-of-resistance-thermometers\/\">Calibration of Resistance Thermometers<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-96971e18 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<h3 class=\"wp-block-heading\">DAkkS Measurement Uncertainty<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-92953039 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong><strong>low measurement uncertainties with DAkkS calibration certificate<\/strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>Temperature fixed points from Argon Triple Point -189.3442 \u00b0C to Tin Freezing Point 231.928 \u00b0C<\/strong><\/p>\n<\/div>\n\n\n\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"585\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-L-eXacal-Klasmeier-3-1024x585-1.png\" alt=\"\" class=\"wp-image-4659\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-L-eXacal-Klasmeier-3-1024x585-1.png 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-L-eXacal-Klasmeier-3-1024x585-1-300x171.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-L-eXacal-Klasmeier-3-1024x585-1-768x439.png 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-L-eXacal-Klasmeier-3-1024x585-1-600x343.png 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:33px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table alignwide pttb\" style=\"font-style:normal;font-weight:400\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>Range<\/strong><\/th><th><strong>Temperature Fixed Points<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Measurement Uncertainty<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">-189.3442 \u00b0C \u2013 0.01 \u00b0C <\/td><td>Argon to Water<\/td><td class=\"has-text-align-center\" data-align=\"center\">12 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">-38.8344 \u00b0C \u2013 0.01 \u00b0C<\/td><td>Mercury to Water<\/td><td class=\"has-text-align-center\" data-align=\"center\">10 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C \u2013 29.7646 \u00b0C<\/td><td>Water to Gallium<\/td><td class=\"has-text-align-center\" data-align=\"center\">12 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C \u2013 156.5985 \u00b0C<\/td><td>Water to Indium<\/td><td class=\"has-text-align-center\" data-align=\"center\">11 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C \u2013 231.928 \u00b0C<\/td><td>Water to Tin<\/td><td class=\"has-text-align-center\" data-align=\"center\">11 mK<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">The stated measurement uncertainties correspond to k=2, include an ITS-90 deviation function, self-heating, and hysteresis, and are specified for the respective range.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Manufacturer: Klasmeier \/ eXacal Model: Pt100L<\/p>\n","protected":false},"featured_media":17115,"template":"","meta":[],"product_brand":[],"product_cat":[756],"product_tag":[715,782,733,832,717,785,696,716,718,864,720,722,837],"class_list":["post-17112","product","type-product","status-publish","has-post-thumbnail","product_cat-precision-thermometers-2","product_tag-1-10-din-pt100","product_tag-calibration","product_tag-dakks","product_tag-dakks-calibration-2","product_tag-precision-thermometer-2","product_tag-prt","product_tag-pt100","product_tag-reference-standard","product_tag-reference-thermometers","product_tag-resistance-thermometers","product_tag-temperature-sensor-2","product_tag-temperature-standard","product_tag-thermometers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product\/17112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media\/17115"}],"wp:attachment":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media?parent=17112"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_brand?post=17112"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_cat?post=17112"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_tag?post=17112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}