{"id":16776,"date":"2024-02-20T15:55:35","date_gmt":"2024-02-20T14:55:35","guid":{"rendered":"https:\/\/www.klasmeier.com\/produkt\/pt100-model-m-medium-temperatureprecision-thermometer-100-c-to-250-c\/"},"modified":"2026-10-29T15:27:08","modified_gmt":"2026-10-29T14:27:08","slug":"pt100-model-m-medium-temperatureprecision-thermometer-100-c-to-250-c","status":"publish","type":"product","link":"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-model-m-medium-temperatureprecision-thermometer-100-c-to-250-c\/","title":{"rendered":"Pt100 Model M Medium-Temperature\nPrecision Thermometer \n(-100 \u00b0C to 250 \u00b0C)"},"content":{"rendered":"\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-12cf9d4c wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"82\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png\" alt=\"\" class=\"wp-image-4288\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png 449w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited-300x55.png 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Precision resistance thermometer with a<strong> thin metal sheath and extra small ceramic measuring resistor. <\/strong>This eXacal thermometer was developed to <strong>determine radial and vertical temperature profiles<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark>  Temperature range:<strong><strong> -100 \u00b0C to 250 \u00b0C<\/strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> small measurement uncertainties:<br\/>between <strong>5 mK and 10 mK<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>fast response times due to thin metal sheath <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>excellent thermal coupling due to small temperature sensor<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark>  ideal for determining<strong> vertical temperature gradients<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp\" alt=\"\" class=\"wp-image-13158\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-150x150.webp 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-768x768.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-600x600.webp 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-100x100.webp 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent.webp 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">This eXacal thermometer was developed to determine vertical and radial temperature profiles in calibration facilities as a component of measurement uncertainty. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is required by several guidelines such as <strong>DKD-R 5-4 &#8220;Calibration of Block Calibrators&#8221;, DKD-R 5-3 &#8220;Calibration of Thermocouples&#8221; or DKD-R 5-1 &#8220;Calibration of Resistance Thermometers&#8221;.<\/strong> Furthermore, the thermometer is suitable for <strong>measuring and adjusting heating zones on calibration furnaces<\/strong>. Naturally, the thermometer can also be used for general <strong>precise temperature measurement<\/strong>. <\/p>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-b7a9e8ab wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-container-core-column-is-layout-8c381d87 wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-center\">Not the right product for you?<\/h2>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/high-quality-temperature-measurement-technology-for-precise-results\/\">-&gt; Back to overview<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-96971e18 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<h3 class=\"wp-block-heading\">Calibration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">eXacal thermometers are calibrated in our own <a href=\"https:\/\/www.klasmeier.com\/en\/precise-temperature-calibration-from-klasmeier-calibration-service\/\">DAkkS calibration laboratory<\/a>. The DAkkS accreditation ensures that all calibrations are traceable to national and international standards. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Pt100 M precision thermometers are designed for excellent calibration at temperature fixed points. Measurement uncertainty is calculated from many components. The largest contributions to the measurement uncertainty budget are the reproducibility of the thermometer, ITS-90 deviation function, self-heating, and hysteresis of the temperature sensor. Using the parameters from the calibration certificate, the Pt100 M precision thermometer can be used with the respective deviation function in the temperature range from -38 \u00b0C to 230 \u00b0C.   <\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-5f2b14c0 wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/precise-temperature-calibration-from-klasmeier-calibration-service\/calibration-of-resistance-thermometers\/\">Calibration of Resistance Thermometers<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-96971e18 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<h3 class=\"wp-block-heading\">Measurement Uncertainty<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-92953039 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong><strong><strong>small measurement uncertainties with DAkkS calibration certificate<\/strong><\/strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong><strong>Temperature fixed points from mercury triple point -38.8344 \u00b0C to tin freezing point 231.928 \u00b0C<\/strong><\/strong><\/p>\n<\/div>\n\n\n\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"585\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-eXacal-Klasmeier-1024x585-1.png\" alt=\"\" class=\"wp-image-4673\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-eXacal-Klasmeier-1024x585-1.png 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-eXacal-Klasmeier-1024x585-1-300x171.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-eXacal-Klasmeier-1024x585-1-768x439.png 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-eXacal-Klasmeier-1024x585-1-600x343.png 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:33px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table alignwide pttb\" style=\"font-style:normal;font-weight:400\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>Range<\/strong><\/th><th><strong>Method<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Measurement uncertainty<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">-38.8344 \u00b0C \u2013 0.01 \u00b0C<\/td><td>Mercury to water<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C \u2013 29.7646 \u00b0C<\/td><td>Water to gallium<\/td><td class=\"has-text-align-center\" data-align=\"center\">6 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C \u2013 156.5985 \u00b0C<\/td><td>Water to indium<\/td><td class=\"has-text-align-center\" data-align=\"center\">9 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C \u2013 231.928 \u00b0C<\/td><td>Water to tin<\/td><td class=\"has-text-align-center\" data-align=\"center\">10 mK<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">The stated measurement uncertainties correspond to k=2, include an ITS-90 deviation function, self-heating, and hysteresis, and are specified for the respective range.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Manufacturer: Klasmeier \/ eXacal Model: Pt100M<\/p>\n","protected":false},"featured_media":16787,"template":"","meta":[],"product_brand":[],"product_cat":[684],"product_tag":[717,716,718,720,722,837],"class_list":["post-16776","product","type-product","status-publish","has-post-thumbnail","product_cat-thermometers-for-special-applications","product_tag-precision-thermometer-2","product_tag-reference-standard","product_tag-reference-thermometers","product_tag-temperature-sensor-2","product_tag-temperature-standard","product_tag-thermometers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product\/16776","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media\/16787"}],"wp:attachment":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media?parent=16776"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_brand?post=16776"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_cat?post=16776"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_tag?post=16776"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}