{"id":16749,"date":"2024-02-29T17:20:51","date_gmt":"2024-02-29T16:20:51","guid":{"rendered":"https:\/\/www.klasmeier.com\/produkt\/secondary-sprt-reference-thermometer-200-c-to-250-c\/"},"modified":"2026-10-21T13:28:06","modified_gmt":"2026-10-21T11:28:06","slug":"secondary-sprt-reference-thermometer-200-c-to-250-c","status":"publish","type":"product","link":"https:\/\/www.klasmeier.com\/en\/produkt\/secondary-sprt-reference-thermometer-200-c-to-250-c\/","title":{"rendered":"Secondary SPRT Reference Thermometer<br\/><b>-200 \u00b0C to 250 \u00b0C<\/b>"},"content":{"rendered":"\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-12cf9d4c wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns alignwide are-vertically-aligned-top is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image alignleft is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-1024x1024.jpg\" alt=\"Low-Temperature Thermometer: The Robust Secondary SPRT Reference Thermometer for Accurate Temperature Measurements\" class=\"wp-image-5410\" style=\"border-radius:50px;width:304px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-1024x1024.jpg 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216-100x100.jpg 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_SPRT_Klasmeier_216.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<p class=\"wp-block-paragraph\"><strong>Low-Temperature Thermometer: The Robust Secondary SPRT Reference Thermometer for Accurate Temperature Measurements<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-size: 14pt;\">Our low-temperature SPRT (Standard Platinum Resistance Thermometer) serves as a robust calibration standard for the most demanding applications in precision temperature measurement. Developed to meet the needs of research, industry, and quality assurance, these thermometers offer excellent accuracy and reliability. Their robustness makes them an attractive alternative to often very sensitive thermometers with quartz protection tubes for everyday measurement tasks.  <\/span><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-b7a9e8ab wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-container-core-column-is-layout-8c381d87 wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-center\">Not the right product for you?<\/h2>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/shop\/\">-&gt; Back to overview<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"82\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png\" alt=\"\" class=\"wp-image-4288\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png 449w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited-300x55.png 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-group alignwide is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-f6ecff61 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center\"><strong>Features of Secondary SPRT Model 216: <\/strong><\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>Protective Gas Filling:<\/strong> The handle of the SPRT is gas-tight, allowing the thermometer to be filled with protective gas. This design shields the thermometer from environmental influences, thereby improving its performance, especially at extremely low temperatures. <span>The protective gas filling enables the thermometer to be used at temperatures down to -200 \u00b0C, which permits calibration down to the argon triple point at approximately -189 \u00b0C.<\/span>  <\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i> <\/mark><span><strong>Temperature Range:<\/strong> With an operating range from -200 \u00b0C to 250 \u00b0C, our Secondary SPRT Reference Thermometer Model 216 covers a low-temperature range. This makes it a versatile solution for various measurement requirements. <\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp\" alt=\"\" class=\"wp-image-13158\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-150x150.webp 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-768x768.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-600x600.webp 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-100x100.webp 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent.webp 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>Small Measurement Uncertainties:<\/strong> The thermometer&#8217;s precision is underscored by its low measurement uncertainties of only 4.5 mK to 7 mK with DAkkS accredited calibration according to DIN EN ISO\/IEC 17025. This excellent accuracy ensures reliable results in all application areas. <\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>Robustness:<\/strong> As a robust alternative to very sensitive SPRTs with a quartz sheath, our Secondary SPRT Reference Thermometer stands out due to its metal sheath and stable measuring resistors. This makes it ideal for long-term use. <\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>New SPRT Sensor:<\/strong> The newly developed Klasmeier <\/span>SPRT temperature sensor has been improved in the following areas:<\/p>\n\n\n\n<ul class=\"wp-block-list is-style-checkmark-list\">\n<li>fast response time <\/li>\n\n\n\n<li>low hysteresis <\/li>\n\n\n\n<li>low self-heating<\/li>\n\n\n\n<li>excellent reproducibility and stability<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group alignwide is-vertical is-layout-flex wp-container-core-group-is-layout-9b5fcf50 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center\"><strong>DAkkS-Certified Calibration of Low-Temperature SPRTs<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><span>In our in-house <strong><a href=\"https:\/\/www.klasmeier.com\/en\/precise-temperature-calibration-from-klasmeier-calibration-service\/\" data-type=\"link\" data-id=\"https:\/\/www.klasmeier.com\/kalibrierdienst-klasmeier\/\">DAkkS-accredited calibration laboratory<\/a><\/strong>, we offer high-precision calibration services for low-temperature SPRTs. Our accreditation guarantees that every calibration is performed according to the internationally recognized standards of <strong>DIN EN ISO\/IEC 17025<\/strong>. This ensures seamless traceability to national and international standards.  <\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span>Our Secondary SPRT Reference Thermometer for low temperatures is specifically designed to be calibrated at temperatures down to the argon triple point. This enables applications in the very low-temperature range that require reliable temperature measurement. <\/span><\/p>\n\n\n\n<figure class=\"wp-block-image size-large has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"567\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-1024x567.png\" alt=\"Measurement Uncertainty: Secondary SPRT Reference Thermometer Model 216\" class=\"wp-image-6205\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-1024x567.png 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-300x166.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-768x425.png 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-1536x850.png 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-2048x1134.png 2048w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/SPRT-216-eXacal-Klasmeier-600x332.png 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-95fa6ccb\"><\/div>\n\n\n\n<figure class=\"wp-block-table pttb\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Range<\/strong><\/td><td><strong>Temperature Fixed Points<\/strong><\/td><td><strong>Measurement Uncertainty<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">-189.3442 \u00b0C &#8211; 0.01 \u00b0C<\/td><td>Argon to Water<\/td><td>6 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">-38.8344 \u00b0C &#8211; 0.01 \u00b0C<\/td><td>Mercury to Water<\/td><td>6 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C &#8211; 29.7646 \u00b0C<\/td><td>Water to Gallium<\/td><td>6 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C &#8211; 156.5985 \u00b0C<\/td><td>Water to Indium<\/td><td>6 mK<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.01 \u00b0C &#8211; 231.928 \u00b0C<\/td><td>Water to Tin<\/td><td>7 mK<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">The stated measurement uncertainties correspond to k=2, include an ITS-90 deviation function, self-heating, and hysteresis, and are specified for the respective range.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-a7cf8a65 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading\"><strong>What Makes Our Calibration Special?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>Traceability:<\/strong> Through our DAkkS accreditation, every calibration is directly linked to national and international standards. This gives you the assurance that your measurement results are recognized worldwide. <\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>Measurement Uncertainty:<\/strong> The accuracy of our calibration is based on a careful evaluation of all uncertainty components, including the reproducibility of the thermometer, the ITS-90 deviation function, the self-heating, and the hysteresis of the sensor.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span><strong>Application Range:<\/strong> With the detailed information from the calibration certificate, you can use your low-temperature SPRT in the <strong>temperature range from -189 \u00b0C to 232 \u00b0C<\/strong> with complete confidence.<\/span><\/p>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<p>Model: eXacal 216 Manufacturer: Klasmeier<\/p>\n","protected":false},"featured_media":16750,"template":"","meta":[],"product_brand":[],"product_cat":[700],"product_tag":[830,702,786],"class_list":["post-16749","product","type-product","status-publish","has-post-thumbnail","product_cat-standard-platinum-resistance-thermometer-sprt","product_tag-secondary-sprt-2","product_tag-sprt","product_tag-standard-platinum-resistance-thermometer","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product\/16749","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media\/16750"}],"wp:attachment":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media?parent=16749"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_brand?post=16749"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_cat?post=16749"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/product_tag?post=16749"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}