{"id":3190,"date":"2024-04-18T20:35:28","date_gmt":"2024-04-18T18:35:28","guid":{"rendered":"https:\/\/www.klasmeier.com\/thermometerkalibrierung-bei-niedrigen-temperaturen\/"},"modified":"2025-05-07T11:29:01","modified_gmt":"2025-05-07T09:29:01","slug":"thermometerkalibrierung-bei-niedrigen-temperaturen","status":"publish","type":"page","link":"https:\/\/www.klasmeier.com\/en\/thermometerkalibrierung-bei-niedrigen-temperaturen\/","title":{"rendered":"Thermometer calibration at low temperatures"},"content":{"rendered":"\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-80fb368b wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"750\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen.jpg\" alt=\"\" class=\"wp-image-2579\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen.jpg 1600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen-300x141.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen-1024x480.jpg 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen-768x360.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen-1536x720.jpg 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Header-tiefe-Temperaturen-600x281.jpg 600w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-c9b5e92c wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<h3 class=\"wp-block-heading\"><strong>DAkkS calibration of thermometers at low temperatures<\/strong><\/h3>\n\n\n\n<p>Do you want to calibrate thermometers at extremely low temperatures? But the temperature range of the calibration baths and standardised procedures used is not sufficient for you? Then you&#8217;ve come to the right place. We use boiling nitrogen to extend the temperature range.<\/p>\n\n\n\n<p>With the three calibration procedures shown here, you can have thermometers calibrated by us DAkkS in the <strong>temperature range from -180 \u00b0C to -80 \u00b0C<\/strong> and at the <strong>fixed temperatures of -189 \u00b0C and <\/strong><br><strong>-196 \u00b0C<\/strong>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image size-full has-custom-border hvr-grow\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat.jpg\" alt=\"\" class=\"wp-image-2581\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-100x100.jpg 100w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-80fb368b wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<h2 class=\"wp-block-heading alignwide has-text-align-center\">Calibration at low temperatures<strong><br>Overview of our DAkkS calibration services<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-5d045043 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group hvr-grow has-accent-background-color has-background is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-386451ff wp-block-group-is-layout-flex\" style=\"border-radius:50px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center\" style=\"font-style:normal;font-weight:800\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\">Ar<\/mark><\/strong><\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">-189 \u00b0C<\/h3>\n\n\n\n<p class=\"has-text-align-center\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.625), 20px);\">ITS-90 calibration<br>down <strong>to the triple point<br>of argon<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/produkt\/dakks-kalibrierung-sprt\/\">Request calibration<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group hvr-grow has-accent-background-color has-background is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-386451ff wp-block-group-is-layout-flex\" style=\"border-radius:50px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center\" style=\"font-style:normal;font-weight:800\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><strong>LN<sub>2<\/sub><\/strong><\/mark><\/strong><\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">-196 \u00b0C<\/h3>\n\n\n\n<p class=\"has-text-align-center\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.625), 20px);\">Thermometer calibration with<br><strong>liquid nitrogen<\/strong> as reference temperature<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/produkt\/dakks-kalibrierung-prt-vergleich\/\">Request calibration<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group hvr-grow has-accent-background-color has-background is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-386451ff wp-block-group-is-layout-flex\" style=\"border-radius:50px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<h4 class=\"wp-block-heading has-text-align-center\" style=\"font-style:normal;font-weight:400\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-chart-line fa-2x\"><\/i><\/mark><\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\">-180 \u00b0C to -80 \u00b0C<\/h3>\n\n\n\n<p class=\"has-text-align-center\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.625), 20px);\">Thermometer calibration with<br><strong>freely selectable calibration points<\/strong> in the nitrogen cryostat<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-outline is-style-outline--3\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/produkt\/dakks-kalibrierung-prt-vergleich\/\">Request calibration<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-c9b5e92c wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image alignleft size-full is-resized has-custom-border hvr-grow\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-Eiskristallbildung.png\" alt=\"\" class=\"wp-image-2587\" style=\"border-radius:50px;width:305px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-Eiskristallbildung.png 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-Eiskristallbildung-300x300.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-Eiskristallbildung-150x150.png 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Cryostat-Eiskristallbildung-100x100.png 100w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<h3 class=\"wp-block-heading\"><strong><strong>With the boiling nitrogen we can:<\/strong><\/strong><\/h3>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>Calibrate thermocouples and resistance thermometers with freely selectable calibration temperatures between -180 \u00b0C and -80 \u00b0C in the DAkkS nitrogen cryostat.<\/strong><br><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>Use the boiling point of nitrogen and calibrate thermometers at -196 \u00b0C DAkkS.<\/strong><br><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>put the argon triple point into operation at -189.3442 \u00b0C and carry out a complete ITS-90 DAkkS calibration in the temperature range from -189 \u00b0C to 0 \u00b0C.<br>The fixed points used are:<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-911a4333 wp-block-group-is-layout-flex\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0\">\n<div style=\"height:100px;width:50px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-b30579f5\"><\/div>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>Argon triple point -189,3442 \u00b0C<\/strong><br><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>Mercury triple point -38,8344 \u00b0C<\/strong><br><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>Water triple point 0,01 \u00b0C<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-80fb368b wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-group alignwide has-border-color has-accent-3-border-color has-global-padding is-layout-constrained wp-container-core-group-is-layout-806f303f wp-block-group-is-layout-constrained\" style=\"border-width:2px;border-radius:25px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-65e523f9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\">\n<p class=\"has-text-align-right\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-file-contract fa-4x\"><\/i><\/mark><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:95%\">\n<p><strong><strong>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of SPRTs at temperature fixed points (SPRT, Pt 25, Pt 2.5, Pt 0.25)<\/strong><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>The accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of ITS-90 Standard Platinum Resistance Thermometers (SPRT) is performed at ITS-90 fixed points.<\/p>\n\n\n\n<details class=\"wp-block-details alignwide is-style-default is-layout-flow wp-block-details-is-layout-flow\"><summary>learn more<\/summary>\n<p><span>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of a Standard Platinum Resistance Thermometer (SPRT) (WGa = 1.11807 or WHg = 0.844235) at the fixed points (freezing points, melting points, and triple points) of the ITS-90. Achievable DAkkS measurement uncertainties, including the ITS-90 deviation function (k=2):<\/span><\/p>\n\n\n\n<figure style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\" class=\"wp-block-table\"><table><tbody><tr><td><strong><span>Temperature Fixed Point<\/span><\/strong><\/td><td><span><strong>in \u00b0C<\/strong><\/span><\/td><td><span><strong>Measurement Uncertainty<\/strong><\/span><\/td><\/tr><tr><td><span>Argon Triple Point<\/span><\/td><td><span>-189.3442 \u00b0C<\/span><\/td><td><span>5.5 mK<\/span><\/td><\/tr><tr><td><span>Mercury Triple Point<\/span><\/td><td><span>-38.8344 \u00b0C<\/span><\/td><td><span>3.5 mK<\/span><\/td><\/tr><tr><td><span>Water Triple Point<\/span><\/td><td><span>0.01 \u00b0C<\/span><\/td><td><span>2.5 mK<\/span><\/td><\/tr><tr><td><span>Gallium Melting Point<\/span><\/td><td><span>29.7646 \u00b0C<\/span><\/td><td><span>2.5 mK<\/span><\/td><\/tr><tr><td><span>Indium Freezing Point<\/span><\/td><td><span>156.5985 \u00b0C<\/span><\/td><td><span>5.5 mK<\/span><\/td><\/tr><tr><td><span>Tin Freezing Point<\/span><\/td><td><span>231.928 \u00b0C<\/span><\/td><td><span>4.5 mK<\/span><\/td><\/tr><tr><td><span>Zinc Freezing Point<\/span><\/td><td><span>419.527 \u00b0C<\/span><\/td><td><span>4.5 mK<\/span><\/td><\/tr><tr><td><span>Aluminum Freezing Point<\/span><\/td><td><span>660.323 \u00b0C<\/span><\/td><td><span>7.0 mK<\/span><\/td><\/tr><tr><td><span>Silver Freezing Point<\/span><\/td><td><span>961.78 \u00b0C<\/span><\/td><td><span>12 mK<\/span><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><span>The fixed points are selected according to the temperature ranges of the ITS-90. The temperature ranges of the ITS-90 are as follows:<\/span><\/p>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/ITS-90-Klasmeier.png\" alt=\"\" class=\"wp-image-9598\"\/><\/figure>\n<\/div>\n\n\n\n<p><span>Before calibration, the Standard Platinum Resistance Thermometer (SPRT) is sufficiently aged. Hydrostatic pressure effects that occur in the fixed-point cells are corrected. The self-heating of the Standard Platinum Resistance Thermometer (SPRT) is examined before the calibration begins and is taken into account when presenting the calibration results. The calibration results include the resistance and W-values of the Standard Platinum Resistance Thermometer (SPRT), as well as two calibration curves (coefficients) calculated according to ITS-90 (with measurement currents of 0 mA and 1 mA unless otherwise specified).<\/span><\/p>\n\n\n\n<p><span>The calibration in the range from Argon (-189 \u00b0C) to the Water Triple Point (0.01 \u00b0C) additionally includes the specification of a measurement uncertainty for extrapolation according to EURAMET TG 01:2017 (up to the Nitrogen Boiling Point, ~196 \u00b0C) with a measurement uncertainty of 7 mK (k=2).<\/span><\/p>\n\n\n\n<p><span>The <strong>minimum immersion depth<\/strong> of the Standard Platinum Resistance Thermometer (SPRT) is:<\/span><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4b827052 wp-block-group-is-layout-flex\">\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span>at<\/span><strong><span> -189 \u00b0C: 400 mm<\/span><\/strong><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> at <strong>962 \u00b0C: 450 mm<\/strong>&nbsp;<\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> in range <strong>-38 \u00b0C to 660 \u00b0C: 300 mm<\/strong><\/p>\n<\/div>\n\n\n\n<p><span>The <strong>maximum outer diameter<\/strong> is <strong>8 mm<\/strong>.<\/span><\/p>\n\n\n\n<p><span>Calibration duration: approximately 5-7 working days or as agreed.<\/span><\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-d565fcec wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#anfragen\">request calibration<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide has-border-color has-accent-3-border-color has-global-padding is-layout-constrained wp-container-core-group-is-layout-806f303f wp-block-group-is-layout-constrained\" style=\"border-width:2px;border-radius:25px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-65e523f9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\">\n<p class=\"has-text-align-right\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-file-contract fa-4x\"><\/i><\/mark><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:95%\">\n<p><strong><strong>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of a resistance thermometer at temperature fixed points (PRT, Pt 100, Pt 1000)<\/strong><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>The accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of resistance thermometers (Pt100, Pt1000) is performed at ITS-90 fixed points.<\/p>\n\n\n\n<details class=\"wp-block-details alignwide is-style-default is-layout-flow wp-block-details-is-layout-flow\"><summary>learn more<\/summary>\n<p><span>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of a resistance thermometer at the fixed points (melting points &amp; triple points) of the ITS-90. Achievable DAkkS measurement uncertainties, including the ITS-90 deviation function (k=2):<\/span><\/p>\n\n\n\n<figure style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\" class=\"wp-block-table\"><table><tbody><tr><td><strong><span>Temperature Fixed Point<\/span><\/strong><\/td><td><span><strong>in \u00b0C<\/strong><\/span><\/td><td><span><strong>Measurement Uncertainty<\/strong><\/span><\/td><\/tr><tr><td><span>Argon Triple Point<\/span><\/td><td><span>-189.3442 \u00b0C<\/span><\/td><td><span>10 mK<\/span><\/td><\/tr><tr><td><span>Mercury Triple Point<\/span><\/td><td><span>-38.8344 \u00b0C<\/span><\/td><td><span>3.5 mK<\/span><\/td><\/tr><tr><td><span>Water Triple Point<\/span><\/td><td><span>0.01 \u00b0C<\/span><\/td><td><span>2.5 mK<\/span><\/td><\/tr><tr><td><span>Gallium Melting Point<\/span><\/td><td><span>29.7646 \u00b0C<\/span><\/td><td><span>2.5 mK<\/span><\/td><\/tr><tr><td><span>Indium Freezing Point<\/span><\/td><td><span>156.5985 \u00b0C<\/span><\/td><td><span>5.5 mK<\/span><\/td><\/tr><tr><td><span>Tin Freezing Point<\/span><\/td><td><span>231.928 \u00b0C<\/span><\/td><td><span>7.0 mK<\/span><\/td><\/tr><tr><td><span>Zinc Freezing Point<\/span><\/td><td><span>419.527 \u00b0C<\/span><\/td><td><span>12 mK<\/span><\/td><\/tr><tr><td><span>Aluminum Freezing Point<\/span><\/td><td><span>660.323 \u00b0C<\/span><\/td><td><span>20 mK<\/span><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">The achievable measurement uncertainties depend on the test specimen.&nbsp;<\/figcaption><\/figure>\n\n\n\n<p><span>The fixed points are selected according to the temperature ranges of the ITS-90. The temperature ranges of the ITS-90 are as follows:<\/span><\/p>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/ITS-90-Klasmeier.png\" alt=\"\" class=\"wp-image-9598\"\/><\/figure>\n<\/div>\n\n\n\n<p><span>Before calibration, the resistance thermometer is sufficiently aged. Hydrostatic pressure effects occurring in the fixed-point cells are corrected. The self-heating of the resistance thermometer is examined before the calibration begins and is taken into account when presenting the calibration results. The calibration results include the resistance and W-values of the resistance thermometer, as well as two calibration curves (coefficients) calculated according to ITS-90 (with measurement currents of 0 mA and 1 mA unless otherwise specified).<\/span><\/p>\n\n\n\n<p><span>The minimum immersion depth of the resistance thermometer is:<\/span><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4b827052 wp-block-group-is-layout-flex\">\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <span>at &#8211;<strong>189 \u00b0C: 400 mm<\/strong><\/span><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> in range from <strong>-38 \u00b0C to 660 \u00b0C: 300 mm<\/strong>&nbsp;<\/p>\n<\/div>\n\n\n\n<p><span>The <strong>maximum outer diameter<\/strong> is <strong>8 mm.<\/strong><\/span><\/p>\n\n\n\n<p><span>Calibration duration: approximately 5 working days or as agreed.<\/span><\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-d565fcec wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#anfragen\">request calibration<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide has-border-color has-accent-3-border-color has-global-padding is-layout-constrained wp-container-core-group-is-layout-806f303f wp-block-group-is-layout-constrained\" style=\"border-width:2px;border-radius:25px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-65e523f9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\">\n<p class=\"has-text-align-right\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-file-contract fa-4x\"><\/i><\/mark><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:95%\">\n<p><strong><strong>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of a resistance thermometer via comparison calibration from -196 \u00b0C to 961 \u00b0C<\/strong><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of a resistance thermometer in the range from -196 \u00b0C to 961 \u00b0C.<\/p>\n\n\n\n<details class=\"wp-block-details alignwide is-style-default is-layout-flow wp-block-details-is-layout-flow\"><summary>learn more<\/summary>\n<p><span>Accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of a resistance thermometer in a calibration bath or furnace, in a nitrogen cryostat, or at boiling nitrogen at 5 temperature points (distributed across the calibration range or as specified by the customer). The following measurement uncertainties can be achieved (depending on the test specimen):<\/span><\/p>\n\n\n\n<figure style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\" class=\"wp-block-table\"><table><tbody><tr><td><span><strong>Calibration Range<\/strong><\/span><\/td><td><span><strong>Measurement Uncertainty<\/strong><\/span><\/td><td><span><strong>Calibration Method<\/strong><\/span><\/td><\/tr><tr><td><span>-196 \u00b0C<\/span><\/td><td><span>15 mK<\/span><\/td><td><span>Nitrogen Boiling Point<\/span><\/td><\/tr><tr><td><span>-180 \u00b0C to -80 \u00b0C<\/span><\/td><td><span>60 mK<\/span><\/td><td><span>Nitrogen Cryostat<\/span><\/td><\/tr><tr><td><span>-80 \u00b0C to -60 \u00b0C<\/span><\/td><td><span>15 mK<\/span><\/td><td rowspan=\"3\"><span><br>Calibration Bath<br><\/span><span>&nbsp;&nbsp;<\/span><\/td><\/tr><tr><td><span>-60 \u00b0C to 90 \u00b0C<\/span><\/td><td><span>10 mK<\/span><\/td><\/tr><tr><td><span>90 \u00b0C to 200 \u00b0C<\/span><\/td><td><span>30 mK<\/span><\/td><\/tr><tr><td><span>200 \u00b0C to 500 \u00b0C<\/span><\/td><td><span>40 mK<\/span><\/td><td rowspan=\"3\"><span><br>Calibration Furnace<\/span><br><span><br><\/span><\/td><\/tr><tr><td><span>500 \u00b0C to 660 \u00b0C<\/span><\/td><td><span>50 mK<\/span><\/td><\/tr><tr><td><span>660 \u00b0C to 961 \u00b0C<\/span><\/td><td><span>150 mK<\/span><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><span>Before calibration, the resistance thermometer is sufficiently aged. The self-heating and hysteresis of the resistance thermometer are examined before the start of the calibration and are taken into account when presenting the calibration results.<\/span><\/p>\n\n\n\n<p><span>Calibration duration: approximately 5 working days or as agreed.<\/span><\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-d565fcec wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#anfragen\">request calibration<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide has-border-color has-accent-3-border-color has-global-padding is-layout-constrained wp-container-core-group-is-layout-806f303f wp-block-group-is-layout-constrained\" style=\"border-width:2px;border-radius:25px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-65e523f9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\">\n<p class=\"has-text-align-right\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-accent-3-color\"><i class=\"fas fa-file-contract fa-4x\"><\/i><\/mark><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:95%\">\n<p><strong><strong>Accredited comparison calibration according to DIN EN ISO\/IEC 17025 (DAkkS) of non-noble metal thermocouples, e.g., Type N<\/strong><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>Comparison calibration of non-noble metal thermocouples against reference thermocouples.<\/p>\n\n\n\n<details class=\"wp-block-details alignwide is-style-default is-layout-flow wp-block-details-is-layout-flow\"><summary>learn more<\/summary>\n<p><strong><span>Comparison calibration of non-noble metal thermocouples against reference thermocouples<\/span><\/strong><\/p>\n\n\n\n<p><span>Comparison calibration against reference thermocouples.<\/span><\/p>\n\n\n\n<p><span>DAkkS measurement uncertainty:<\/span><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong><span>Temperature Range<\/span><\/strong><\/td><td><strong><span>Measurement Uncertainty<\/span><\/strong><\/td><td><strong><span>Calibration Method<\/span><\/strong><\/td><\/tr><tr><td><span>-196 \u00b0C<\/span><span><br><\/span><\/td><td><span>1.0 K<\/span><\/td><td><span>Nitrogen Boiling Point<\/span><\/td><\/tr><tr><td><span>-180 \u00b0C to -80 \u00b0C<\/span><\/td><td><span>1.0 K<\/span><\/td><td><span>Nitrogen Cryostat<\/span><\/td><\/tr><tr><td><span>-80 \u00b0C to 0 \u00b0C<\/span><\/td><td><span>1.0 K<\/span><\/td><td><span>Calibration Bath<\/span><\/td><\/tr><tr><td><span>0 \u00b0C to 961 \u00b0C<\/span><\/td><td><span>1.5 K<\/span><\/td><td rowspan=\"2\"><span><br>Calibration Furnace<br><\/span><\/td><\/tr><tr><td><span>961 \u00b0C to 1200 \u00b0C<\/span><\/td><td><span>2.5 K<\/span><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The <strong>minimum immersion depth<\/strong> of the thermometer is <strong>190 mm (at -196 \u00b0C: 300 mm)<\/strong>.<br>The <strong>maximum outer diameter is 8 mm<\/strong>.<br>The achievable measurement uncertainties depend on the test specimen.<\/p>\n\n\n\n<p><span>Calibration duration: approximately 5 working days or as agreed.<\/span><\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-d565fcec wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#anfragen\">request calibration<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-7a94f013 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center\"><strong>Technical background<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-6bfd910c wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\">\n<p>Calibrating thermometers at extremely low temperatures is a technical challenge. Conventionally, calibration baths or temperature block calibrators are used to calibrate thermometers in the negative temperature range. However, these quickly reach their limits when cooling and are only used down to around -80 \u00b0C.<\/p>\n\n\n\n<p>Calibration baths are cooled with compressors. To ensure stable control of the calibration temperature, an electric heater works \u2018against\u2019 the compressor, which always cools at maximum power. In addition, the calibration media used (such as silicone or ethanol) change their viscosity considerably and absorb water from the ambient humidity. Both of these factors make it difficult to control the temperature of the calibration baths. The lowest temperature that calibration baths with stable control can reach is around -80 \u00b0C.<\/p>\n\n\n\n<p>Temperature block calibrators are cooled with Peltier elements or Sterling motors. These technologies are limited and can be used down to about -50 \u00b0C with Peltier elements or -100 \u00b0C with Sterling motors.<\/p>\n\n\n\n<p>To overcome these limitations, we use liquid nitrogen as a \u2018cold source\u2019. This enables us to extend the temperature range when calibrating thermometers down to -196 \u00b0C.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border hvr-grow\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"450\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Kalibrierung-Cryostat-Stickstoff.png\" alt=\"\" class=\"wp-image-2593\" style=\"border-radius:30px;width:417px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Kalibrierung-Cryostat-Stickstoff.png 598w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Kalibrierung-Cryostat-Stickstoff-300x226.png 300w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-80fb368b wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"671\" height=\"86\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/KlasmeierCloud.png\" alt=\"\" class=\"wp-image-3223\" style=\"border-radius:25px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/KlasmeierCloud.png 671w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/KlasmeierCloud-300x38.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/KlasmeierCloud-600x77.png 600w\" sizes=\"auto, (max-width: 671px) 100vw, 671px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-ef350914 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<h3 class=\"wp-block-heading alignwide\">New digital archive Klasmeier Cloud:<br><strong><strong>Calibration documents quickly and easily available<\/strong><\/strong><\/h3>\n\n\n\n<p>The new Klasmeier Cloud \u2013 the perfect archive for all calibration documents. From now on, our customers will find a QR code on all devices calibrated by Klasmeier, with which they can quickly and easily access our digital archive. <\/p>\n\n\n\n<p>Especially useful: In addition to all calibration documents, the contact details of the relevant contact person at Klasmeier are also always available there. So even five or more years from now, if you have any questions about your calibration product, you can find the information you need with just one click.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<p class=\"has-text-align-center\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-cloud-download fa-6x\"><\/i><\/mark><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink is-style-fill\"><a class=\"wp-block-button__link wp-element-button\" href=\"\/en\/cloud\/\">To Klasmeier Cloud<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<h2 class=\"wp-block-heading alignwide has-text-align-center\"><strong><strong>Finding the right calibration solution for you<\/strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-b6a795d6 wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"333\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/BK.png\" alt=\"\" class=\"wp-image-1608\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/BK.png 500w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/BK-300x200.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-text-align-center\">Questions about our calibration services?<\/h3>\n\n\n\n<p class=\"has-text-align-center\"><br><strong><strong><strong>Please send your questions or enquiries to Mr Boris Kalb<\/strong>:<\/strong><\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-envelope\"><\/i> <\/mark><a href=\"https:\/\/www.klasmeier.com\/en\/unternehmen\/nehmen-sie-kontakt-mit-uns-auf\/\">Get in touch now<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide has-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-7c68bf55 wp-block-group-is-layout-constrained\" id=\"anfragen\" style=\"border-radius:25px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<h3 class=\"wp-block-heading\"><strong>Request calibration<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-contact-form-7-contact-form-selector\">\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f7905-o1\" lang=\"de-DE\" dir=\"ltr\" data-wpcf7-id=\"7905\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/pages\/3190#wpcf7-f7905-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Kontaktformular\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"7905\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"de_DE\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f7905-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<style>\n\n\/* Allgemeine Stile f\u00fcr das Formular *\/\n.wpcf7-form {\n max-width: 1280px; \/* Volle Breite setzen *\/\n margin: 0 auto; \/* Zentrieren *\/\n box-sizing: border-box;\n padding-top: 0px; \/* Abstand nach oben *\/\n}\n\n\/* Stile f\u00fcr die Zeilen und Spalten *\/\n.form-row {\n display: flex;\n flex-wrap: wrap;\n justify-content: space-between;\n margin-bottom: 10px; \/* Abstand zwischen den Zeilen *\/\n}\n\n.form-column {\n width: 48%; \/* Zwei Spalten mit Abstand *\/\n box-sizing: border-box;\n}\n\n\/* Anpassung der H\u00f6he der Eingabefelder und der vollen Breite *\/\n.wpcf7-form input[type=\"text\"],\n.wpcf7-form input[type=\"email\"],\n.wpcf7-form textarea {\n font-size: 20px;\n height: 60px; \/* Erh\u00f6hte H\u00f6he der Eingabefelder *\/\n width: 400px; \/* Volle Breite der Spalte *\/\n padding: 10px; \/* Innenabstand f\u00fcr Eingabefelder *\/\n box-sizing: border-box;\n border-radius: 15px; \/* Abgerundete Ecken *\/\n border: 1px solid #ccc; \/* Rand um die Eingabefelder *\/\n transition: width 0.5s ease;\n}\n\n.wpcf7-form textarea {\n max-height: 150px;\n height: auto; \/* Erm\u00f6glicht flexible H\u00f6he *\/\n min-height: 120px; \/* Mindesth\u00f6he f\u00fcr mehrzeiliges Schreiben *\/\n resize: none; \/* Entfernt die Gr\u00f6\u00dfen\u00e4nderungsoption *\/\n}\n\n.wpcf7-form input[type=\"text\"]:hover,\n.wpcf7-form input[type=\"email\"]:hover,\n.wpcf7-form textarea:hover {\n width: 560px;\n border: 2px solid #DD3333;\n}\n\n.wpcf7 input[type=\"text\"]:focus,\n.wpcf7 textarea[type=\"text\"]:focus,\n.wpcf7 input[type=\"email\"]:focus,\n.wpcf7 textarea[type=\"email\"]:focus{\n width: 560px;\n outline: none;\n box-shadow: none;\n border: 3px solid #DD3333;\n}\n\n.wpcf7 input[type=\"checkbox\"] {\n width: 15px; \/* \u00c4ndert die Breite der Checkbox *\/\n height: 15px; \/* \u00c4ndert die H\u00f6he der Checkbox *\/\n transform: scale(1.5); \/* Vergr\u00f6\u00dfert die Checkbox *\/\n margin-right: 10px; \/* Abstand zwischen Checkbox und Text *\/\n -webkit-appearance: none; \/* Entfernt die Standard-Stilierung *\/\n appearance: none; \/* Entfernt die Standard-Stilierung *\/\n border: 1px solid #ccc; \/* Rand der Checkbox *\/\n border-radius: 8px; \/* Abgerundete Ecken *\/\n background-color: #f0f0f0; \/* Hintergrundfarbe der Checkbox *\/\n position: relative; \/* Erm\u00f6glicht die Positionierung des Haken-Pseudo-Elements *\/\n cursor: pointer; \/* \u00c4ndert den Cursor bei Hover *\/\n transition: background-color 0.3s, border-color 0.3s; \/* Smooth Transition *\/\n vertical-align: middle; \/* Richtet die Checkbox vertikal aus *\/\n}\n\n.wpcf7 input[type=\"checkbox\"]:checked {\n background-color: #DD3333; \/* Hintergrundfarbe wenn angeklickt *\/\n border-color: #DD3333; \/* Randfarbe wenn angeklickt *\/\n}\n\n.wpcf7 input[type=\"checkbox\"]:checked::after {\n content: '';\n position: absolute;\n top: 40%;\n left: 48%;\n width: 4px; \/* Breite des Hakens *\/\n height: 7px; \/* H\u00f6he des Hakens *\/\n border: solid white;\n border-width: 0 2px 2px 0;\n transform: translate(-50%, -50%) rotate(45deg);\n}\n\n.wpcf7 input[type=\"checkbox\"]:focus {\n outline: none;\n box-shadow: 0 0 2px 2px rgba(0, 123, 255, 0.25); \/* Optionale Hervorhebung bei Fokus *\/\n}\n\n\/* Platzhalterstile *\/\n::placeholder {\n color: #888; \/* Farbe f\u00fcr Platzhaltertext *\/\n font-size: 20px;\n}\n\n\/* Stile f\u00fcr die Checkboxen *\/\n.wpcf7-form p {\n margin-bottom: 10px;\n display: flex;\n align-items: center;\n text-align: center;\n}\n\n.wpcf7-form p label {\n margin-left: 5px;\n margin-bottom: 0; \/* Kein zus\u00e4tzlicher Abstand unten *\/\n display: flex;\n align-items: center;\n text-align: center;\n}\n\n.wpcf7 .wpcf7-submit {\n display: block; \/* Sicherstellen, dass der Button als Blockelement behandelt wird *\/\n margin: 0 auto; \/* Automatisches Zentrieren *\/\n}\n\n.wpcf7 .wpcf7-submit-container {\n text-align: center; \/* Zentriert den Button-Container *\/\n margin-top: 20px; \/* Optional: Abstand oberhalb des Containers *\/\n}\n\n.wpcf7-submit {\n background-color: #DD3333; \/* Hintergrundfarbe des Buttons *\/\n color: white; \/* Textfarbe des Buttons *\/\n border: none; \/* Kein Rahmen *\/\n padding: 15px 30px; \/* Innenabstand des Buttons *\/\n text-align: center; \/* Textzentrierung *\/\n text-decoration: none; \/* Kein Textdekor *\/\n display: block; \/* Als Blockelement behandeln *\/\n font-size: 20px; \/* Schriftgr\u00f6\u00dfe *\/\n margin: 0px auto; \/* Au\u00dfenabstand *\/\n margin-left: 25px; \/* Kleiner linker Abstand *\/\n cursor: pointer; \/* Cursor bei Hover *\/\n border-radius: 15px; \/* Abgerundete Ecken *\/\n transition: background-color 0.3s ease, transform 0.3s ease; \/* \u00dcbergangseffekte *\/\n}\n\n.wpcf7-submit:hover {\n background-color: #DD3333; \/* Hintergrundfarbe bei Hover *\/\n transform: scale(1.05); \/* Vergr\u00f6\u00dferung bei Hover *\/\n}\n\n.wpcf7-submit:active {\n background-color: #DD3333; \/* Hintergrundfarbe bei Klick *\/\n transform: scale(1.02); \/* Leichte Verkleinerung bei Klick *\/\n}\n\n.wpcf7 .wpcf7-spinner {\n display: block; \/* Als Blockelement behandeln *\/\n position: absolute; \/* Absolute Positionierung innerhalb des Containers *\/\n top: 100%; \/* Abstand vom oberen Rand des Containers *\/\n left: 50%; \/* Zentriert horizontal innerhalb des Containers *\/\n transform: translateX(-50%); \/* Zur\u00fcckverschieben um die H\u00e4lfte der eigenen Breite *\/\n}\n\n@media screen and (max-width: 600px) {\n .wpcf7 input[type=\"checkbox\"] {\n width: 50px !important;\n height: 20px !important;\n margin-right: 10px;\n border-radius: 50%; \/* Rund statt 8px *\/\n }\n\n}\n\n\n@media screen and (max-width: 768px) {\n \/* Spalten untereinander *\/\n .form-row {\n flex-direction: column;\n }\n\n .form-column {\n width: 100% !important;\n margin-bottom: 10px;\n }\n\n .wpcf7-form input[type=\"text\"],\n .wpcf7-form input[type=\"email\"],\n .wpcf7-form input[type=\"tel\"],\n .wpcf7-form textarea {\n width: 100% !important;\n }\n\n \/* Checkbox bleibt rund und linksb\u00fcndig *\/\n .wpcf7 input[type=\"checkbox\"] {\n width: 20px;\n height: 20px;\n margin-right: 10px;\n border-radius: 50%; \/* Rund statt 8px *\/\n }\n\n \/* Optional: Upload-Feld auch bei Bedarf zentrieren *\/\n .codedropz-upload-container {\n padding: 30px 15px;\n }\n\n .codedropz-upload-inner {\n width: 100%;\n box-sizing: border-box;\n }\n\n .codedropz-btn-wrap {\n justify-content: center;\n }\n}\n\n\n@media screen and (max-width: 1350px) {\n .wpcf7-form input[type=\"text\"],\n .wpcf7-form input[type=\"email\"],\n .wpcf7-form input[type=\"tel\"],\n .wpcf7-form textarea {\n transition: none !important;\n width: 100% !important;\n }\n\n .wpcf7-form input[type=\"text\"]:hover,\n .wpcf7-form input[type=\"email\"]:hover,\n .wpcf7-form input[type=\"tel\"]:hover,\n .wpcf7-form textarea:hover,\n .wpcf7 input[type=\"text\"]:focus,\n .wpcf7 input[type=\"email\"]:focus,\n .wpcf7 input[type=\"tel\"]:focus,\n .wpcf7 textarea:focus {\n width: 100% !important;\n border: 2px solid #DD3333;\n }\n}\n<\/style>\n<div class=\"form-row\">\n\t<div class=\"form-column\">\n\t\t<p><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"vorname\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" id=\"vorname\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"First Name\" value=\"\" type=\"text\" name=\"vorname\" \/><\/span>\n\t\t<\/p>\n\t\t<p><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"nachname\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" id=\"nachname\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Last Name\" value=\"\" type=\"text\" name=\"nachname\" \/><\/span>\n\t\t<\/p>\n\t\t<p><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" id=\"email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"email\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n\t<div class=\"form-column\">\n\t\t<p><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"firma\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" id=\"firma\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Company\" value=\"\" type=\"text\" name=\"firma\" \/><\/span>\n\t\t<\/p>\n\t\t<p><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"nachricht\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea wpcf7-validates-as-required\" id=\"nachricht\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Message (optional)\" name=\"nachricht\"><\/textarea><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<p><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"Datenschutz\"><span class=\"wpcf7-form-control wpcf7-checkbox wpcf7-validates-as-required\"><span class=\"wpcf7-list-item first last\"><label><input type=\"checkbox\" name=\"Datenschutz[]\" value=\"I agree to the storage of my data in accordance with the privacy policy.\" \/><span class=\"wpcf7-list-item-label\">I agree to the storage of my data in accordance with the privacy policy.<\/span><\/label><\/span><\/span><\/span>\n<\/p>\n<p class=\"wpcf7-form-control-wrap\"><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Send Request\" \/>\n<\/p>\n<p><input type=\"hidden\" name=\"page-info\" id=\"page-info\" value=\"\" \/>\n<\/p>\n<p><script>\ndocument.addEventListener('DOMContentLoaded', function () {\n var pageInfoField = document.querySelector('#page-info');\n if (pageInfoField) {\n var pageTitle = document.title;\n var pageURL = window.location.href;\n pageInfoField.value = pageTitle + ' (' + pageURL + ')';\n }\n});\n<\/script>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>DAkkS calibration of thermometers at low temperatures Do you want to calibrate thermometers at extremely low temperatures? But the temperature range of the calibration baths and standardised procedures used is not sufficient for you? Then you&#8217;ve come to the right place. We use boiling nitrogen to extend the temperature range. With the three calibration procedures [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3190","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages\/3190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/comments?post=3190"}],"version-history":[{"count":18,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages\/3190\/revisions"}],"predecessor-version":[{"id":11955,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages\/3190\/revisions\/11955"}],"wp:attachment":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media?parent=3190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}