{"id":16591,"date":"2024-05-16T17:55:32","date_gmt":"2024-05-16T15:55:32","guid":{"rendered":"https:\/\/www.klasmeier.com\/exacal-precision-thermometers\/"},"modified":"2026-10-21T13:10:27","modified_gmt":"2026-10-21T11:10:27","slug":"exacal-precision-thermometers","status":"publish","type":"page","link":"https:\/\/www.klasmeier.com\/en\/exacal-precision-thermometers\/","title":{"rendered":"eXacal &#8211; Precision Thermometers"},"content":{"rendered":"\n<div class=\"wp-block-cover alignfull\"><img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"500\" class=\"wp-block-cover__image-background wp-image-4258\" alt=\"\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT-1.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT-1.jpg 1500w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT-1-300x100.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT-1-1024x341.jpg 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT-1-768x256.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT-1-600x200.jpg 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-contrast-background-color has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container has-global-padding is-layout-constrained wp-block-cover-is-layout-constrained\">\n<h1 class=\"wp-block-heading has-text-align-center alignfull has-base-2-color has-text-color has-link-color wp-elements-1\" id=\"e-xacal-prazisionsthermometer\" style=\"font-size:clamp(46.18px, 2.886rem + ((1vw - 3.2px) * 4.565), 90px);\"><strong>eXacal Precision Thermometers<\/strong><\/h1>\n<\/div><\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<figure class=\"wp-block-image aligncenter size-full is-resized hvr-grow\"><a href=\"https:\/\/exacal.de\/\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"82\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png\" alt=\"eXacal\" class=\"wp-image-4288\" style=\"width:482px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png 449w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited-300x55.png 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/a><\/figure>\n\n\n\n<div class=\"wp-block-group alignwide is-nowrap is-layout-flex wp-container-core-group-is-layout-180f4183 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-buttons mobilebtn is-content-justification-space-between is-layout-flex wp-container-core-buttons-is-layout-70428311 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#SPRT\">SPRT<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Pr&#xE4;zisionsthermometer\">Precision Thermometers<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Industrielle-Referenzthermometer\">Industrial Reference Thermometers<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Thermometer-f&#xFC;r-Spezialanwendungen\">Thermometers for Special Applications<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Eintauchthermometer\">Immersion Thermometers<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Rundgang\">Tour<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Fertigungsverfahren\">Manufacturing Processes<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Messwiderst&#xE4;nde\">Measuring Resistors<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#3D-Druckverfahren\">3D Printing Processes<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Inhomogenit&#xE4;ten-Scanner\">Inhomogeneity Scanner<\/a><\/div>\n\n\n\n<div class=\"wp-block-button hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"#Technologie\">Technology<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-rank-math-toc-block alignwide displaynone\" id=\"rank-math-toc\"><h2>Table of Contents<\/h2><nav><ul><li><a href=\"#e-xacal-prazisionsthermometer\">eXacal Precision Thermometers<\/a><ul><li><a href=\"#widerstandsthermometer-und-thermoelemente\">Resistance Thermometers and Thermocouples<\/a><\/li><li><a href=\"#primares-its-90-sprt\">Primary ITS-90 SPRT \u2013 Our High-End Thermometer\n-200 \u00b0C to 670 \u00b0C<\/a><\/li><li><a href=\"#sekundaeres-sprt\">Secondary SPRT \u2013 The Robust Alternative for Daily Laboratory Use<\/a><\/li><li><a href=\"#prazisionsthermometer\">Precision Thermometers<\/a><ul><li><a href=\"#modelle\">Models:<\/a><\/li><\/ul><\/li><li><a href=\"#industrielle-referenzthermometer\">Industrial Reference Thermometers<\/a><ul><li><a href=\"#modelle-1-1\">Models:<\/a><\/li><\/ul><\/li><li><a href=\"#thermometer-fur-spezialanwendungen\">Thermometers for Special Applications<\/a><ul><li><a href=\"#modelle-2\">Models:<\/a><\/li><li><a href=\"#ihre-ansprechpartnerin-fur-prazisionsthermometer\">\nYour Contact Person for Precision Thermometers:<\/a><\/li><\/ul><\/li><li><a href=\"#thermometer-manufaktur-prazisionsthermometer-in-handarbeit\">Thermometer Manufactory \u2013 Handcrafted Precision Thermometers<\/a><ul><li><a href=\"#einen-rundgang-durch-die-thermometer-manufaktur-sehen-sie-im-video\">Watch the video for a tour of the thermometer manufactory:<\/a><\/li><li><a href=\"#das-fertigungsverfahren-im-uberblick\">Overview of the Manufacturing Process<\/a><ul><li><a href=\"#mechanische-fertigung\">Mechanical Production<\/a><\/li><li><a href=\"#edelmetall-schweissverfahren\">Precious Metal Welding Process<\/a><\/li><li><a href=\"#laserschweissen\">Laser Welding<\/a><\/li><li><a href=\"#thermische-behandlung-von-thermomaterial\">Thermal Treatment of Thermocouple Material<\/a><\/li><li><a href=\"#alterung-von-widerstandsthermometern\">Aging of Resistance Thermometers<\/a><\/li><li><a href=\"#drahtspulen-wickeln\">Winding Wire Coils<\/a><\/li><li><a href=\"#reinigung-von-keramikkomponenten-im-rohrofen\">Cleaning of Ceramic Components in a Tube Furnace<\/a><\/li><\/ul><\/li><li><a href=\"#messwiderstande-aus-eigener-fertigung\">Temperature Sensors \u2013 Precision from In-House Production<\/a><\/li><li><a href=\"#3-d-druckverfahren\">Modern 3D Printing Technology<\/a><\/li><li><a href=\"#inhomogenitaten-scanner\">Inhomogeneity Scanner<\/a><\/li><\/ul><\/li><li><a href=\"#e-xacal-technologie\">eXacal Technology<\/a><ul><li><a href=\"#der-handgriff-als-technologietrager\">The Handle as a Technology Carrier<\/a><\/li><li><a href=\"#temperatursensoren\">Temperature Sensors<\/a><\/li><li><a href=\"#thermometerdraht\">Thermometer Wire<\/a><\/li><li><a href=\"#schutzrohre\">Protection Tubes<\/a><\/li><li><a href=\"#anschlussleitungen\">Connection Cables<\/a><\/li><li><a href=\"#hochwertiger-e-xacal-tragekoffer\">High-Quality eXacal Carrying Case<\/a><\/li><li><a href=\"#gemeinsam-die-richtige-losung-fur-sie-finden\">Finding the Right Solution Together<\/a><\/li><li><a href=\"#sprechen-sie-direkt-mit-unserem-experten\">Speak directly with our expert!<\/a><\/li><\/ul><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-group alignwide has-global-padding is-layout-constrained wp-container-core-group-is-layout-67525f0d wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-center alignfull\" id=\"widerstandsthermometer-und-thermoelemente\">Resistance Thermometers and Thermocouples<\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">eXacal precision thermometers measure <strong>precise temperatures from \u2212200 \u00b0C to 1200 \u00b0C<\/strong> and serve as a <strong>reference for the calibration<\/strong> of other thermometers. Depending on the application, they are available as <strong>Standard Platinum Resistance Thermometers (SPRT), Pt100 resistance thermometers, or precious metal thermocouples<\/strong>. <\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">We manufacture them by hand in our manufactory in Fulda: from design and construction of the temperature sensor to accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS).<\/p>\n\n\n\n<div id=\"SPRT\" class=\"wp-block-group has-accent-background-color has-background is-vertical is-layout-flex wp-container-core-group-is-layout-a3da003a wp-block-group-is-layout-flex\" style=\"border-top-left-radius:50px;border-top-right-radius:50px;border-bottom-left-radius:50px;border-bottom-right-radius:50px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40)\">\n<p class=\"has-contrast-2-color has-text-color has-link-color has-small-font-size wp-elements-2 wp-block-paragraph\"><strong>Highlight \u00b7 High End \u00b7 ITS-90 <\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left\" id=\"primares-its-90-sprt-das-high-end-thermometer\"><strong>Primary ITS-90 SPRT \u2013 Our High-End Thermometer<\/strong><br\/><strong>-200 \u00b0C to 670 \u00b0C<\/strong><\/h2>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-9760934e\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:73%\">\n<p class=\"wp-block-paragraph\">The <strong>primary Standard Platinum Resistance Thermometer<\/strong> <strong>meets<\/strong> <strong>all requirements of the ITS-90<\/strong> (International Temperature Scale of 1990). <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is designed for maximum accuracy and thus represents the highest level of precision thermometry \u2013 ideal as a <strong>primary calibration standard<\/strong> in research, national metrology tasks, and wherever the <strong>lowest possible measurement uncertainty<\/strong> is required.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/produkt\/primary-standard-platinum-resistance-thermometer-sprt-200-c-to-670-c\/\">To the Primary SPRT<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:27%\">\n<figure class=\"wp-block-image alignright size-medium has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-300x300.jpg\" alt=\"\" class=\"wp-image-4265\" style=\"border-top-left-radius:50px;border-top-right-radius:50px;border-bottom-left-radius:50px;border-bottom-right-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-1024x1024.jpg 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto-100x100.jpg 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Klasmeier-SPRT_Produktfoto.jpg 1500w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignwide has-accent-background-color has-background is-vertical is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-cde7d848 wp-block-group-is-layout-flex\" style=\"border-top-left-radius:50px;border-top-right-radius:50px;border-bottom-left-radius:50px;border-bottom-right-radius:50px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40)\">\n<h2 class=\"wp-block-heading has-text-align-left\" id=\"primares-its-90-sprt-das-high-end-thermometer-1\"><strong>Secondary SPRT \u2013 The Robust Alternative for Daily Laboratory Use<\/strong><\/h2>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-9760934e\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:73%\">\n<p class=\"wp-block-paragraph\">The secondary SPRT is the <strong>more durable alternative for daily use in the laboratory<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It does not meet all ITS-90 requirements but still offers <strong>excellent accuracy and long-term stability<\/strong>. <br\/>This makes it the right tool for all demanding everyday applications where a stable, reliable, and less sensitive SPRT is required.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:27%\">\n<figure class=\"wp-block-image alignright size-medium has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-SPRT-Klasmeier-216-300x300.jpeg\" alt=\"\" class=\"wp-image-6531\" style=\"border-top-left-radius:50px;border-top-right-radius:50px;border-bottom-left-radius:50px;border-bottom-right-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-SPRT-Klasmeier-216-300x300.jpeg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-SPRT-Klasmeier-216-150x150.jpeg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-SPRT-Klasmeier-216-100x100.jpeg 100w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-SPRT-Klasmeier-216.jpeg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:2px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-1abe4828\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\"><strong>Our secondary SPRT models at a glance:<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Secondary SPRT Reference Thermometer<br\/>(-200 \u00b0C to 250 \u00b0C)<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link has-text-align-center wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/produkt\/secondary-sprt-reference-thermometer-200-c-to-250-c\/\">To the SPRT<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Secondary SPRT Reference Thermometer<br\/>(-100 \u00b0C to 430 \u00b0C)<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline is-style-outline--3\"><a class=\"wp-block-button__link has-text-align-center wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/produkt\/secondary-sprt-reference-thermometer-100-c-to-430-c\/\">To the SPRT<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Secondary SPRT Reference Thermometer<br\/>(-100 \u00b0C to 670 \u00b0C)<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline is-style-outline--4\"><a class=\"wp-block-button__link has-text-align-center wp-element-button\" href=\"https:\/\/www.klasmeier.com\/produkt\/sekundaeres-sprt-referenzthermometer-exacal_215_670\/\">To the SPRT<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"Pr\u00e4zisionsthermometer\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-group alignwide has-global-padding is-layout-constrained wp-container-core-group-is-layout-19b45eff wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-center alignwide\" id=\"prazisionsthermometer\"><strong>Precision Thermometers<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Our precision thermometers are ideal as a <strong>temperature standard for calibrations or for accurate temperature measurements<\/strong>. Available as <strong>resistance thermometers (Pt100)<\/strong> and as <strong>precious metal thermocouples of types R\/S\/B, Pt\/Pd, and Pt\/Au<\/strong>. Our eXacal precision thermometers are a <strong>robust alternative to the extremely sensitive ITS-90 Standard Platinum Resistance Thermometers (SPRTs)<\/strong>. The eXacal thermocouples are manufactured <strong>with a stainless steel reference junction<\/strong>.   <\/p>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<figure class=\"wp-block-image aligncenter size-large is-resized hvr-grow\"><img loading=\"lazy\" decoding=\"async\" width=\"1006\" height=\"1024\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-1006x1024.webp\" alt=\"\" class=\"wp-image-11211\" style=\"width:392px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-1006x1024.webp 1006w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-295x300.webp 295w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-768x782.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-1508x1536.webp 1508w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-2011x2048.webp 2011w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-HS-600x611.webp 600w\" sizes=\"auto, (max-width: 1006px) 100vw, 1006px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-0049d611 wp-block-group-is-layout-flex\">\n<h4 id=\"modelle\" class=\"wp-block-heading\"><strong>Models:<\/strong><\/h4>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-62aae154\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pt100<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-f0b6b26e wp-block-group-is-layout-flex\">\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/pt100-typ-l-niedrig-temperatur-praezisionsthermometer\/\">Precision Thermometer Pt100 Model L <strong>(-200 \u00b0C to 250 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-model-m-medium-temperatureprecision-thermometer-100-c-to-250-c\/\" data-type=\"link\" data-id=\"https:\/\/www.klasmeier.com\/produkt\/modell-m\/\">Precision Thermometer Pt100 Model M <strong>(-100 \u00b0C to 250 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/pt100-typ-n-medium-temperatur-praezisionsthermometer\/\" data-type=\"link\" data-id=\"https:\/\/www.klasmeier.com\/produkt\/pt100-modell-n-medium-temperatur-praezisionsthermometer-100-c-bis-420-c\/\">Precision Thermometer Pt100 Model N <strong>(-100 \u00b0C to 420 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/pt100-typ-h-temperatur-praezisionsthermometer-100-c-bis-660-c\/\">Precision Thermometer Pt100 Model H <strong>(-100 \u00b0C to 660 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/pt100-typ-hs-hoch-temperatur-praezisionsthermometer-0c-bis-850c-2\/\">Precision Thermometer Pt100 Model HS <strong>(0 \u00b0C to 850 \u00b0C)<\/strong><\/a><\/p>\n<\/div>\n\n\n\n<div style=\"height:21px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-62aae154\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Precious Metal Thermocouples<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-f0b6b26e wp-block-group-is-layout-flex\">\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/typ-r-thermoelement\/\">Thermocouple Type R <strong>(0 \u00b0C to 1200 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/type-s-precision-thermocouple-0-c-to-1200-c\/\">Thermocouple Type S <strong>(0 \u00b0C to 1200 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/typ-b-praezisions-thermoelement-0c-bis-1500c\/\">Thermocouple Type B <strong>(0 \u00b0C to 1500 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt-pd-precision-thermocouple-0-c-to-1500-c\/\">Thermocouple Pt\/Pd <strong>(0 \u00b0C to 1500 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> Thermocouple Pt\/Au<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"Industrielle-Referenzthermometer\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-group alignwide has-global-padding is-layout-constrained wp-container-core-group-is-layout-19b45eff wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-center alignwide\" id=\"industrielle-referenzthermometer\"><strong>Industrial Reference Thermometers<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Industrial Reference Thermometers (Pt100 and precious metal thermocouples)<\/strong> are perfectly suited for <strong>industrial use in traceable temperature measurements<\/strong> or as <strong>secondary standards in industrial calibrations<\/strong> (for example, in a dry-block calibrator).<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized hvr-grow\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"2502\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-scaled.webp\" alt=\"\" class=\"wp-image-11419\" style=\"width:411px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-scaled.webp 2560w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-300x293.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-1024x1001.webp 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-768x751.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-1536x1501.webp 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-2048x2002.webp 2048w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-IH-im-Bockkalibrator-600x586.webp 600w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-0049d611 wp-block-group-is-layout-flex\">\n<h4 id=\"modelle-1-1\" class=\"wp-block-heading\"><strong>Models:<\/strong><\/h4>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-62aae154\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pt100<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-f0b6b26e wp-block-group-is-layout-flex\">\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/pt100-i-industrielle-referenzthermometer\/\">Pt100 Model I <strong>(-100 \u00b0C to 250 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-in-industrial-reference-thermometer-100-c-400-c\/\">Pt100 Model IN <strong>(-100 \u00b0C to 400 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-ih-industrial-reference-thermometer-100-c-to-660-c\/\">Pt100 Model IH <strong>(-100 \u00b0C to 660 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-ihw-industrial-reference-thermometer-angled-100-c-660-c\/\">Pt100 Model IHW (angled) <strong>(-100 \u00b0C to 660 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-iw-industrial-reference-thermometer-angled-100-c-to-250-c\/\">Pt100 Model IW (angled) <strong>(-100 \u00b0C to 250 \u00b0C)<\/strong><\/a><\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><br\/><strong>Precious Metal Thermocouples<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-00f2c586 wp-block-group-is-layout-flex\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0\">\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/type-r-industrial-reference-thermocouple-0-c-to-1200-c\/\">Thermocouple Type R <strong>(0 \u00b0C to 1200 \u00b0C<\/strong><\/a><strong>) <\/strong> <\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/type-s-industrial-reference-thermocouple-0-c-to-1200-c\/\">Thermocouple Type S <strong>(0 \u00b0C to 1200 \u00b0C)<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-fd3ce590 wp-block-group-is-layout-constrained\" id=\"Thermometer-f\u00fcr-Spezialanwendungen\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h2 class=\"wp-block-heading has-text-align-center alignwide\" id=\"thermometer-fur-spezialanwendungen\"><strong>Thermometers for Special Applications<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.542), 1.2rem);\"><strong>Custom Designs:<\/strong> We also manufacture precision thermometers according to your individual requirements, such as <strong>differential thermometers, angled temperature probes, and thermometers based on specific customer requests<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized hvr-grow\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"2555\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-scaled.webp\" alt=\"\" class=\"wp-image-11105\" style=\"width:390px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-scaled.webp 2560w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-300x300.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-1024x1022.webp 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-150x150.webp 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-768x766.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-1536x1533.webp 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-2048x2044.webp 2048w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-600x599.webp 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Pt100-Modell-M-Hangriff-100x100.webp 100w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-f0d5df8b wp-block-group-is-layout-flex\">\n<h4 id=\"modelle-2\" class=\"wp-block-heading\"><strong>Models:<\/strong><\/h4>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-f0b6b26e wp-block-group-is-layout-flex\">\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/modell-m\/\">Precision Thermometer Pt100 Model M <strong>(-100 \u00b0C to 250 \u00b0C)<\/strong><\/a> for immersion depth studies and rapid measurement<br\/><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/produkt\/temperatur-differenz-thermoelement\/\">Type R \/ Type S Temperature Differential Thermocouple <strong>(0 \u00b0C to 1200 \u00b0C)<\/strong><\/a><\/p>\n\n\n\n<p class=\"hvr-forward wp-block-paragraph\"><i class=\"fas fa-arrow-right\"><\/i> <a href=\"https:\/\/www.klasmeier.com\/en\/produkt\/pt100-type-d-temperature-difference-thermometer-100-c-250-c\/\">Pt100 Type D Temperature Differential Thermometer<strong> (-100 \u00b0C to 250 \u00b0C)<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--10);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center alignwide\" id=\"haben-sie-fragen-zu-unseren-prazisionsthermometern\"><strong>Do you have questions about our precision thermometers?<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-a31f37fe wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"333\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/ES.png\" alt=\"\" class=\"wp-image-2653\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/ES.png 500w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/ES-300x200.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"sprechen-sie-direkt-mit-unserer-expertin\">Speak directly with our expert!<\/h3>\n\n\n\n<h4 class=\"wp-block-heading has-text-align-center\" id=\"ihre-ansprechpartnerin-fur-prazisionsthermometer\"><br\/><strong>Your contact person for <strong>precision thermometers<\/strong>: <\/strong><\/h4>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Elke Seewald<\/strong> <a href=\"https:\/\/www.linkedin.com\/in\/elke-seewald-a436071aa\/\" target=\"_blank\" rel=\"noopener\"><span class=\"wp-rich-text-font-awesome-icon wp-font-awesome-icon\"><svg aria-hidden=\"true\" focusable=\"false\" data-prefix=\"fab\" data-icon=\"linkedin\" class=\"svg-inline--fa fa-linkedin \" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\"><path fill=\"currentColor\" d=\"M416 32H31.9C14.3 32 0 46.5 0 64.3v383.4C0 465.5 14.3 480 31.9 480H416c17.6 0 32-14.5 32-32.3V64.3c0-17.8-14.4-32.3-32-32.3zM135.4 416H69V202.2h66.5V416zm-33.2-243c-21.3 0-38.5-17.3-38.5-38.5S80.9 96 102.2 96c21.2 0 38.5 17.3 38.5 38.5 0 21.3-17.2 38.5-38.5 38.5zm282.1 243h-66.4V312c0-24.8-.5-56.7-34.5-56.7-34.6 0-39.9 27-39.9 54.9V416h-66.4V202.2h63.7v29.2h.9c8.9-16.8 30.6-34.5 62.9-34.5 67.2 0 79.7 44.3 79.7 101.9V416z\"><\/path><\/svg><\/span><\/a><br\/><em>Head of the <a href=\"http:\/\/exacal.de\/\" target=\"_blank\" rel=\"noopener\">eXacal <\/a>Manufactory at Klasmeier<\/em><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-envelope\"><\/i><\/mark> <a href=\"https:\/\/www.klasmeier.com\/en\/company\/contacts\/\">Contact now<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"Manufaktur\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"82\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png\" alt=\"\" class=\"wp-image-4288\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited.png 449w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Logo-edited-300x55.png 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center alignwide\" id=\"thermometer-manufaktur-prazisionsthermometer-in-handarbeit\"><strong>Thermometer Manufactory \u2013 Handcrafted Precision Thermometers<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-group alignwide has-global-padding is-layout-constrained wp-container-core-group-is-layout-7b42d209 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-3a88641f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\">\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> Our eXacal <a href=\"https:\/\/www.klasmeier.com\/praezisionsthermometer-von-klasmeier\/\">precision thermometers<\/a> are <strong>in our manufactory in Fulda, Germany<\/strong>, with the utmost care <strong>hand<\/strong><strong>crafted<\/strong> \u2013 and can be customized <strong>to your individual requirements<\/strong> upon request. Whether it is adjustments to the handle, connectors, probe length, or connection cable \u2013 <strong>we implement your wishes with precision<\/strong>. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> Our thermometers are <strong>developed for exact temperature measurements<\/strong> and, depending on the model, cover a wide <strong>temperature range from -200 \u00b0C to 1200 \u00b0C<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> In addition to thermometer design, we place special emphasis on developing our own tools and innovative production processes. From <strong>design<\/strong> and <strong>manufacturing<\/strong> to the final <strong>accredited calibration according to DIN EN ISO\/IEC 17025 (DAkkS)<\/strong>, every step takes place exclusively in-house. Thanks to the <strong>use of high-quality raw materials<\/strong> and the <strong>avoidance of external suppliers<\/strong>, we <strong>guarantee<\/strong> consistently high <strong>quality for our products<\/strong>.  <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent.webp\" alt=\"\" class=\"wp-image-13158\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent.webp 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-300x300.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-150x150.webp 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-768x768.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-600x600.webp 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/klasmeier_EU_Precision_Thermometry_transparent-100x100.webp 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button  hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/thermometer-manufacture\/reliable-precision-thermometers\/\">To the Thermometers<\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1003\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung.jpg\" alt=\"\" class=\"wp-image-1392\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung.jpg 1600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung-300x188.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung-1024x642.jpg 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung-768x481.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung-1536x963.jpg 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/eXacal_Fertigung-600x376.jpg 600w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"Rundgang\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading alignwide\" id=\"einen-rundgang-durch-die-thermometer-manufaktur-sehen-sie-im-video\">Watch the video for a tour of the thermometer manufactory:<\/h3>\n\n\n\n<div class=\"wp-block-group alignwide has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"border-style:none;border-width:0px;border-radius:0px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:0;padding-bottom:0\">\n<figure class=\"wp-block-embed alignwide is-type-video is-provider-vimeo wp-block-embed-vimeo wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Rundgang durch die Thermometer Manufaktur von Klasmeier\" src=\"https:\/\/player.vimeo.com\/video\/768484806?h=8809463295&amp;dnt=1&amp;app_id=122963\" width=\"500\" height=\"281\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe>\n<\/div><\/figure>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"Fertigungsverfahren\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center alignwide\" id=\"das-fertigungsverfahren-im-uberblick\">Overview of the Manufacturing Process<\/h3>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-c99b97d2 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-fertigung-1.jpg\" alt=\"\" class=\"wp-image-2671\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"mechanische-fertigung\" class=\"wp-block-heading\"><strong>Mechanical Production<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Components such as handles or prototypes for development projects are precisely manufactured using machining processes.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-180f4183 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-schweissen-1.jpg\" alt=\"\" class=\"wp-image-2675\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"edelmetall-schweissverfahren\" class=\"wp-block-heading\"><strong>Precious Metal Welding Process<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Thermocouple wires and connection cables are manually welded with the highest precision. The fuel gases required for this, hydrogen and oxygen, are not stored in cylinders but are generated directly from water by electrolysis in an optimal mixing ratio of 2:1. This process ensures particularly high purity of the fuel gas.  <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-180f4183 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Laserschweissen.jpg\" alt=\"\" class=\"wp-image-2677\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"laserschweissen\" class=\"wp-block-heading\"><strong>Laser Welding<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Filigree connections, such as the lead wires of temperature sensors, are welded under a microscope using high-precision lasers.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-180f4183 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-thermische-behandlung-1.jpg\" alt=\"\" class=\"wp-image-2679\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"thermische-behandlung-von-thermomaterial\" class=\"wp-block-heading\"><strong>Thermal Treatment of Thermocouple Material<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">A core competence is the targeted thermal treatment of thermocouple wires. Our aging processes ensure a metallurgically stable and thermoelectrically homogeneous state for eXacal thermocouples. <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-180f4183 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Klasmeier-1.jpg\" alt=\"\" class=\"wp-image-2681\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"alterung-von-widerstandsthermometern\" class=\"wp-block-heading\"><strong>Aging of Resistance Thermometers<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Resistance thermometers are fully stabilized in a specially developed aging furnace flushed with oxygen, following customized aging cycles.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-180f4183 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-SPRT-Draht-Messwiderstaende.jpg\" alt=\"\" class=\"wp-image-2683\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"drahtspulen-wickeln\" class=\"wp-block-heading\"><strong>Winding Wire Coils<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For SPRT measuring resistors, ultra-thin, high-purity platinum wire is precisely wound into the finest wire coils using a specially developed winding machine.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow is-layout-flex wp-container-core-columns-is-layout-180f4183 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Voraltern-der-Keramiken.png\" alt=\"\" class=\"wp-image-2953\" style=\"border-radius:50px;width:308px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:75%\">\n<h4 id=\"reinigung-von-keramikkomponenten-im-rohrofen\" class=\"wp-block-heading\"><strong>Cleaning of Ceramic Components in a Tube Furnace<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">All ceramic components used in our precision thermometers undergo an intensive cleaning process in a tube furnace at high temperatures before use.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"Messwiderst\u00e4nde\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"569\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier.png\" alt=\"\" class=\"wp-image-2687\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier.png 1600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier-300x107.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier-1024x364.png 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier-768x273.png 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier-1536x546.png 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Temperatur-Messwiderstaende-von-Klasmeier-600x213.png 600w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-center hvr-grow is-layout-flex wp-container-core-columns-is-layout-426f0dcf wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Messwiderstaende-von-Klasmeier-1-300x300-1.png\" alt=\"\" class=\"wp-image-2689\" style=\"border-radius:50px;width:281px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Messwiderstaende-von-Klasmeier-1-300x300-1.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Messwiderstaende-von-Klasmeier-1-300x300-1-150x150.png 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Messwiderstaende-von-Klasmeier-1-300x300-1-100x100.png 100w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<h3 id=\"messwiderstande-aus-eigener-fertigung\" class=\"wp-block-heading\">Temperature Sensors \u2013 Precision from In-House Production<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The production of temperature sensors is a craft that requires the highest precision and expertise. In our manufactory, we combine state-of-the-art technology with traditional craftsmanship to carry out this complex process entirely ourselves. With great care and experience, our specialists manually thread ultra-fine platinum wire onto ceramic or quartz support bodies under a microscope. Previously, the wire is formed into a filigree coil on a winding machine, which serves as the basis for our highly sensitive temperature sensors. These delicate components form the heart of our products. In our thermometer manufactory, they are further processed and refined into precision thermometers of the highest quality \u2013 for exact measurement results you can rely on.     <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button  hvr-shrink\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/temperature-sensors-from-klasmeier\/\">To the Measuring Resistors<\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" id=\"3D-Druckverfahren\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"541\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck.jpg\" alt=\"\" class=\"wp-image-2693\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck.jpg 1600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck-300x101.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck-1024x346.jpg 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck-768x260.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck-1536x519.jpg 1536w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D-Druck-600x203.jpg 600w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-center hvr-grow is-layout-flex wp-container-core-columns-is-layout-426f0dcf wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"275\" height=\"275\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D_Druck.jpg\" alt=\"\" class=\"wp-image-2695\" style=\"border-radius:50px;width:281px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D_Druck.jpg 275w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D_Druck-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_3D_Druck-100x100.jpg 100w\" sizes=\"auto, (max-width: 275px) 100vw, 275px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<h3 id=\"3-d-druckverfahren\" class=\"wp-block-heading\">Modern 3D Printing Technology<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">High-precision insulation elements and complex plastic components, such as strain reliefs, are used in our eXacal thermometers. These components are manufactured directly in our production facility using state-of-the-art 3D printing technology. This allows even demanding geometries to be implemented without additional tools or manual intermediate steps. This not only saves time and costs but also enables flexible and customer-specific production of our thermometers using a modular design.   <\/p>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1010\" height=\"383\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Thermoelement-eXacal-Inhomogenitaeten-1-1.png\" alt=\"\" class=\"wp-image-2697\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Thermoelement-eXacal-Inhomogenitaeten-1-1.png 1010w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Thermoelement-eXacal-Inhomogenitaeten-1-1-300x114.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Thermoelement-eXacal-Inhomogenitaeten-1-1-768x291.png 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Thermoelement-eXacal-Inhomogenitaeten-1-1-600x228.png 600w\" sizes=\"auto, (max-width: 1010px) 100vw, 1010px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-fd3ce590 wp-block-group-is-layout-constrained\" id=\"Inhomogenit\u00e4ten-Scanner\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading alignwide\" id=\"inhomogenitaten-scanner\">Inhomogeneity Scanner<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The investigation of possible inhomogeneities in eXacal thermocouples is carried out with a specially developed inhomogeneity scanner. A movable heat source checks the <strong>entire thermocouple material<\/strong> of the measuring point for local deviations. <\/p>\n\n\n\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"568\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Inhomogenitaeten-Scanner-1024x568-1024x568-1.png\" alt=\"\" class=\"wp-image-2699\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Inhomogenitaeten-Scanner-1024x568-1024x568-1.png 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Inhomogenitaeten-Scanner-1024x568-1024x568-1-300x166.png 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Inhomogenitaeten-Scanner-1024x568-1024x568-1-768x426.png 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Klasmeier-Inhomogenitaeten-Scanner-1024x568-1024x568-1-600x333.png 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The inhomogeneity scanner is an innovative in-house development by Klasmeier and contributes significantly to the optimization of eXacal thermocouples. It enables: <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>A more realistic assessment of measurement uncertainties<\/strong><br\/><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>The verification and refinement of thermal treatment processes<\/strong><br\/><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-circle-check\"><\/i><\/mark> <strong>A significant improvement in product quality and manufacturing processes<\/strong><\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-073a9c11 wp-block-group-is-layout-constrained\" id=\"Technologie\" style=\"padding-top:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40)\">\n<h2 class=\"wp-block-heading has-text-align-center alignwide\" id=\"e-xacal-technologie\"><strong>eXacal Technology<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">eXacal precision thermometers have been developed from the ground up. Every component was designed with the greatest care and perfectly matched to the others. A central highlight is the innovative handle, which serves as a central technology carrier. Thanks to its modular design, it allows for a wide variety of eXacal thermometer combinations.   <\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-fd3ce590 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-columns hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-ea6032ec wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"900\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff.jpg\" alt=\"\" class=\"wp-image-2745\" style=\"border-radius:50px;width:388px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff.jpg 900w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Handgriff-100x100.jpg 100w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:70%\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"der-handgriff-als-technologietrager\">The Handle as a Technology Carrier<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Our eXacal thermometers can be assembled almost arbitrarily as a modular system. This is made possible by our aluminum handle, which is fitted with an individually 3D-printed insert for each thermometer. Important components such as strain reliefs, protective gas fillings, or various protection tubes can thus be freely combined.  <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-ea6032ec wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:70%\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"temperatursensoren\">Temperature Sensors<\/h3>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Temperature Sensors from In-House Production<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We manufacture precise temperature sensors in our manufactory. Experienced employees wind platinum wire onto ceramic or quartz bodies. After winding, we form these measuring resistors into precision thermometers.  <\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0aa01211 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline hvr-shrink is-style-outline--6\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.klasmeier.com\/en\/temperature-sensors-from-klasmeier\/\">To the Temperature Sensors<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"900\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand.jpg\" alt=\"\" class=\"wp-image-2749\" style=\"border-radius:50px;width:388px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand.jpg 900w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Messwiderstand-100x100.jpg 100w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-ea6032ec wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"900\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht.jpg\" alt=\"\" class=\"wp-image-2752\" style=\"border-radius:50px;width:388px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht.jpg 900w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Thermometerdraht-100x100.jpg 100w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:70%\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"thermometerdraht\">Thermometer Wire<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">We use precious metals as thermometer wire for the measuring resistors and in the capillaries, rather than standard sheathed wires. Depending on the temperature range, these are pure silver or platinum. This allows us to reduce thermoelectric effects and parasitic voltages within the thermometer.   <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-ea6032ec wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:70%\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"schutzrohre\">Protection Tubes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Protection tubes are selected based on thermal stress and the nature of the atmosphere. To optimally protect the temperature sensor from mechanical and chemical influences, protection tubes made of pure ceramic, precious metals, high-temperature alloys, or sapphire are used depending on the application. <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"900\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1.jpg\" alt=\"\" class=\"wp-image-2759\" style=\"border-radius:50px;width:388px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1.jpg 900w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Schutzrohre-1-100x100.jpg 100w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-ea6032ec wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"900\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1.jpg\" alt=\"\" class=\"wp-image-2761\" style=\"border-radius:50px;width:388px;height:auto\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1.jpg 900w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1-300x300.jpg 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1-150x150.jpg 150w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1-768x768.jpg 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1-600x600.jpg 600w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal_Anschlussleitung-1-100x100.jpg 100w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-left:var(--wp--preset--spacing--10);flex-basis:70%\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"anschlussleitungen\">Connection Cables<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Connection cables for thermocouples and resistance thermometers are assembled by hand. We use copper strands made from a low-stress copper alloy specifically cast for our thermometers. A reinforced textile jacket made of heat-treated fiberglass protective sleeving, which is high-temperature resistant, serves as the insulation. This protects the individual strands from mechanical stress, high temperatures, and organic solvents.   <\/p>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-fd3ce590 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<h3 class=\"wp-block-heading has-text-align-center alignwide\" id=\"hochwertiger-e-xacal-tragekoffer\"><strong>High-Quality eXacal Carrying Case<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">All eXacal thermometers are delivered in a case, but can alternatively be ordered with a high-quality aluminum carrying case. The robust case with a customized foam insert ensures that the sensitive thermometers are well protected during transport and storage.  <\/p>\n\n\n\n<figure class=\"wp-block-image alignwide size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"854\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Produktkoffer-Aluminium.webp\" alt=\"\" class=\"wp-image-16318\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Produktkoffer-Aluminium.webp 1280w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Produktkoffer-Aluminium-300x200.webp 300w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Produktkoffer-Aluminium-1024x683.webp 1024w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Produktkoffer-Aluminium-768x512.webp 768w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/eXacal-Produktkoffer-Aluminium-600x400.webp 600w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-2c1e9e97 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border hvr-float\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"267\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Produktkoffer-exacal-Thermometer.webp\" alt=\"\" class=\"wp-image-16319\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Produktkoffer-exacal-Thermometer.webp 400w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Produktkoffer-exacal-Thermometer-300x200.webp 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border hvr-float\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"267\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Koffer.webp\" alt=\"\" class=\"wp-image-16316\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Koffer.webp 400w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/exacal-Koffer-300x200.webp 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border hvr-float\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"267\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Thermometer-exacal-Koffer.webp\" alt=\"\" class=\"wp-image-16317\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/Thermometer-exacal-Koffer.webp 400w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/Thermometer-exacal-Koffer-300x200.webp 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\">\n<h3 class=\"wp-block-heading has-text-align-center alignwide\" id=\"gemeinsam-die-richtige-losung-fur-sie-finden\"><strong>Finding the Right Solution Together<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-columns alignwide hvr-grow has-accent-background-color has-background is-layout-flex wp-container-core-columns-is-layout-a31f37fe wp-block-columns-is-layout-flex\" style=\"border-radius:50px;margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"333\" src=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/TK.png\" alt=\"\" class=\"wp-image-1440\" style=\"border-radius:50px\" srcset=\"https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/TK.png 500w, https:\/\/www.klasmeier.com\/wp-content\/uploads\/2024\/03\/TK-300x200.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"sprechen-sie-direkt-mit-unserem-experten\">Speak directly with our expert!<\/h3>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><br\/><strong>Your contact person at Klasmeier: <\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Thomas Klasmeier<\/strong> <a href=\"https:\/\/www.linkedin.com\/in\/thomas-klasmeier\/\" target=\"_blank\" rel=\"noopener\"><span class=\"wp-rich-text-font-awesome-icon wp-font-awesome-icon\"><svg aria-hidden=\"true\" focusable=\"false\" data-prefix=\"fab\" data-icon=\"linkedin\" class=\"svg-inline--fa fa-linkedin \" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\"><path fill=\"currentColor\" d=\"M416 32H31.9C14.3 32 0 46.5 0 64.3v383.4C0 465.5 14.3 480 31.9 480H416c17.6 0 32-14.5 32-32.3V64.3c0-17.8-14.4-32.3-32-32.3zM135.4 416H69V202.2h66.5V416zm-33.2-243c-21.3 0-38.5-17.3-38.5-38.5S80.9 96 102.2 96c21.2 0 38.5 17.3 38.5 38.5 0 21.3-17.2 38.5-38.5 38.5zm282.1 243h-66.4V312c0-24.8-.5-56.7-34.5-56.7-34.6 0-39.9 27-39.9 54.9V416h-66.4V202.2h63.7v29.2h.9c8.9-16.8 30.6-34.5 62.9-34.5 67.2 0 79.7 44.3 79.7 101.9V416z\"><\/path><\/svg><\/span><\/a><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#dd3333\" class=\"has-inline-color\"><i class=\"fas fa-envelope\"><\/i><\/mark> <a href=\"https:\/\/www.klasmeier.com\/en\/company\/contacts\/\">Contact now<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Resistance Thermometers and Thermocouples eXacal precision thermometers measure precise temperatures from \u2212200 \u00b0C to 1200 \u00b0C and serve as a reference for the calibration of other thermometers. Depending on the application, they are available as Standard Platinum Resistance Thermometers (SPRT), Pt100 resistance thermometers, or precious metal thermocouples. We manufacture them by hand in our manufactory [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-16591","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages\/16591","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/comments?post=16591"}],"version-history":[{"count":1,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages\/16591\/revisions"}],"predecessor-version":[{"id":16593,"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/pages\/16591\/revisions\/16593"}],"wp:attachment":[{"href":"https:\/\/www.klasmeier.com\/en\/wp-json\/wp\/v2\/media?parent=16591"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}